Hello Aleksandar, I use the following setting and it works well for me: # Huawei E220 # group = modems id = e220 name = "Huawei E220" detect-string = "huawei" init-string = "AT+CNMI=2,1,2,2,0" message-storage = sm #message-storage = "ME" speed = 460800
On Tue, Jan 24, 2012 at 2:56 PM, Aleksandar Smolovic <[email protected]> wrote: > ** > Dear all, > > I am getting error CMS ERROR: 500 when sending SMS messages from web > interface that come with Kannel 1.5.0 > > I have figured out that CMS ERROR: 500 in MY CASE is because: > 1) My modem is, by default, in "text mode" for SMS sending while Kannel > (bearerbox) is sending messages in PDU mode > 2) Kannel, as far as I can see can work only in PDU mode > 3) I have to initialize my modem, not in "text mode", but in PDU mode > > So, CMR ERROR: 500 is showing when there is some kind of inconsistency in > modem configuration (working in text mode trying to send PDU messages... or > vice versa) with having no specific and more precise explanation in error > description ... which sucks... > > Now, I have another problem: > When try using minicom to work with modem using AT commands I can send > messages in PDU mode, let's say: > AT+CMGF=0;+CSCS="UCS2";+CMGS=25 > > xxxxxxxxxxxxxxxxxxxxxxxxxxxxx Ctrl+Z > > and part "xxxxxxxxxxx" I have converted using this tool > http://twit88.com/home/utility/sms-pdu-encode-decode > > this procedure give me message on receiving phone. > > So, it should be same procedure in Kannel - just need to initialize modem > in proper way: > AT+CMGF=0 (work in PDU mode) > AT+CSCS="UCS2" (using Hex) > AT+CMGS=25 (calculated for every particular message, in our case > calculated by Kannel) > xxxxxxxxxxxxxx (calculated by Kannel, containing among other things SMS > Center number and text of SMS message) > > So, I need to add AT+CMGF=0 and AT+CSCS="UCS2" withing init-string of my > Huawei E220 modem. > Till this moment, my initial script line in kannel.conf was: > init-string = "AT+CNMI=2,1,2,2,0;+CMEE=1" > > Now, when I add to above line: +CMGF=0; +CSCS=UCS2 > init-string = "AT+CNMI=2,1,2,2,0;+CMEE=1;+CMGF=0;+CSCS=UCS2" > > I have an error in bearerbox log file - ERROR: Initialization error.... > > I supose I am making mistake in sintax of "init-string = ..." > > I have tried init-string = > "AT+CNMI=2,1,2,2,0;+CMEE=1;+CMGF=0;+CSCS="UCS2"" .... but I've got same > error.... > When put init-string = "AT+CNMI=2,1,2,2,0;+CMEE=1;+CMGF=0" I don't have > initialization error, but have CMS ERROR: and Rerouting error for messages > in queue for sending. When translate PDU message (PDU > ASCII) there is no > sms center number and some other fields... > > Can someone help with this ? Does someone has "working init script" for > this modem ???? > > > -- *Mfawa Alfred Onen* *M.Sc Telecoms, B.Eng Elect/Elect, CCNA, RHCE(in view)* System Administrator Department of Computer Science, Bingham University. E-Mail: [email protected] Phone1: +234 805 944 3154 Phone2: +234 803 079 6088