Hans,
       The wait timer is in mds. MDS delays the DOWN events of
Directors(working on Vdest) by 3 minutes. The reference is
opensaf/services/mds/src/mds_main.c : uns32 MDS_AWAIT_ACTIVE_TMR_VAL =
18000; AvND on payload doesn't get AVD down event till 3 minutes. And
when it gets, it reboots. 

This time had been put large enough to make Switchover success.
Swithover may take some time in putting the components STDBY from
ACTIVE.

You can fine tune it as per your requirements as far as payload is
concerned.

Regards
-Nagendra 

-----Original Message-----
From: [EMAIL PROTECTED]
[mailto:[EMAIL PROTECTED] On Behalf Of Hans Feldt
Sent: Tuesday, November 20, 2007 8:18 PM
To: [email protected]
Subject: Re: [Users] System behavior when both controllerstemporarily
disappears?

I found avnd_di.c:avnd_evt_mds_avd_dn that does a reboot directly from
what I understand. But the payload node seems to wait 3 minutes before
reboot. Where is that in the code?

Thanks,
Hans

Hans Feldt wrote:
> We discussed this a bit in thread:
> http://list.opensaf.org/archives/users/2007-August/000108.html
> 
> I would like the payloads to discover that there is no active 
> controller and reboot themselves. Where in the (avnd) code can I
change this?
> 
> This is a system without HPI enabled.
> 
> Thanks,
> Hans
> 
> _______________________________________________
> Users mailing list
> [email protected]
> http://list.opensaf.org/maillist/listinfo/users
> 

_______________________________________________
Users mailing list
[email protected]
http://list.opensaf.org/maillist/listinfo/users
_______________________________________________
Users mailing list
[email protected]
http://list.opensaf.org/maillist/listinfo/users

Reply via email to