Dear Bogdan
If I only define UDP HEP listener, I will see errors in log file like below:
That's the reason why I add a TCP HEP listener.
To be honest, I can't understand why we need to define HEP listener since 
opensips send SIP trace to homer as a client.
Thanks.


Jan  3 23:47:14 OpenSIPS12 OpenSIPS12[30056]: ERROR:proto_hep:msg_send: trying 
to using proto hep_tcp/9 which is not initialized!
Jan  3 23:47:14 OpenSIPS12 OpenSIPS12[30056]: ERROR:proto_hep:send_hep_message: 
Cannot send hep message!
Jan  3 23:47:14 OpenSIPS12 OpenSIPS12[30056]: 
ERROR:siptrace:send_trace_proto_duplicate: failed to forward message to 
destination!
Jan  3 23:47:14 OpenSIPS12 OpenSIPS12[30056]: ERROR:siptrace:save_siptrace: 
Failed to duplicate with hep to <172.21.253.243:9060>



------------------ Original ------------------
From:  "bogdan";<[email protected]>;
Date:  Jan 4, 2018
To:  "Jeffrey Zhao"<[email protected]>; 
Cc:  "OpenSIPS users mailling list"<[email protected]>; 
Subject:  Re: [OpenSIPS-Users] OpenSIPS 2.3 and Homer 5 configuration



                   Hi Jeffrey,
     
     If you define only the UDP HEP listener :
         listen=hep_udp:172.21.253.242:6666
     and use no TCP enforcement int the HEP id defintion
           modparam("proto_hep", "hep_id",  "[hid]172.21.253.243")
       does it still uses TCP for HEP ??
       
       Regards,
          Bogdan-Andrei Iancu OpenSIPS Founder and Developer   
http://www.opensips-solutions.com OpenSIPS Summit 2018   
http://www.opensips.org/events/Summit-2018Amsterdam      On 01/03/2018 06:03 
PM, Jeffrey Zhao       wrote:
     
            Dear Bogdan
       Bingo!!
       It works after I add below two lines.
       Actually, I realize that if hep listener is not defined,         
opensips won't restart normally.
       
       
                listen=hep_udp:172.21.253.242:6666
         listen=hep_tcp:172.21.253.242:6666
       
                
         
         Now opensips send SIP trace to homer server using TCP.
         Is there any config method to send using UDP, or HEP only           
use TCP?
         
         
         Thanks.
         
         
         
         
         
         
         ------------------ Original ------------------
                    From:  "bogdan";<[email protected]>;
           Date:  Jan 3, 2018
           To:  "OpenSIPS users mailling             
list"<[email protected]>; "Jeffrey             
Zhao"<[email protected]>; 
           Subject:  Re: [OpenSIPS-Users] OpenSIPS 2.3 and             Homer 5 
configuration
         
         
         
         Hi Jeffrey,
           
           Do you have a HEP listener configured in your OpenSIPS:
           
               listen=hep_udp:opensips_IP:some_hep_port 
           
           Best regards,
                  Bogdan-Andrei Iancu OpenSIPS Founder and Developer   
http://www.opensips-solutions.com OpenSIPS Summit 2018   
http://www.opensips.org/events/Summit-2018Amsterdam          On 01/02/2018 
06:55 AM, Jeffrey           Zhao wrote:
         
                    Dear Sir/Madam
           Happy new year!!
           
           
           I am trying to configure OpenSIPS 2.3 with Homer 5 using             
HEP protocol.
           Homer is installed             using: 
https://github.com/sipcapture/homer-installer/blob/opensips-2.3/homer_installer.sh
           
           
           What I want to achieve is to let OpenSIPS to send traced             
SIP message to Homer using HEP protocol, just like what             freeswitch 
did with Homer.
           Is there any document or example I can follow to complete            
 this target?
           
           
           I read and follow the below link to make the             
configuration, but obviously it is outdated, and module             parameters 
in the example is already outdated.
           
           
           https://github.com/sipcapture/homer/wiki/Examples%3A-OpenSIPS
           Section:OpenSIPs - config for trace node.
           
           
           Then, I followed the SIPTrace module document and             
configure, but OpenSIPS doesn't try to connect homer.
           What am I missing?
           
           
           Thank you very much!
           
           
           Best Regards.
           Jeffrey
           
           
                        loadmodule "proto_hep.so"
             loadmodule "siptrace.so"
             
               
             
               
             modparam("siptrace", "trace_on",                 1)
             modparam("proto_hep", "hep_id",                  
"[hid]172.21.253.243")
             modparam("siptrace", "trace_id",                 
"[tid]uri=hep:hid")
           
           
             
                        route{
             
               
                     $var(trace_id) = "tid";
                     $var(user) = "[email protected]";
                                     sip_trace("$var(trace_id)", "t", 
"sip|xlog|rest",                 "$var(user)");
           
           
             
                   ......
                                if                 (is_method("REGISTER"))
                     {
             
               
             
               
                                             sip_trace("$var(trace_id)", "t", 
"sip|xlog|rest",                 "$var(user)");
           
           
           
           
                      
           _______________________________________________ Users mailing list 
[email protected] 
http://lists.opensips.org/cgi-bin/mailman/listinfo/users
_______________________________________________
Users mailing list
[email protected]
http://lists.opensips.org/cgi-bin/mailman/listinfo/users