Hi Bogdan,
It returns the postgres data type uuid. I put that in acc extra field to keep 
track calls. 

If I use following, I'm not getting the warning anymore. 

avp_db_query("SELECT uuid_generate_v1mc()::varchar","$avp(callid)")
 

    On Wednesday, 14 February 2018, 14:55, Bogdan-Andrei Iancu 
<bog...@opensips.org> wrote:
 

  Hi Pasan,
 
 But from the DB point of view, what data type does your procedure return ?
 
 Regards,
  Bogdan-Andrei Iancu

OpenSIPS Founder and Developer
  http://www.opensips-solutions.com
OpenSIPS Summit 2018
  http://www.opensips.org/events/Summit-2018Amsterdam
 On 02/14/2018 08:51 AM, Pasan Meemaduma via Users wrote:
  
  Hi List,
  
  I got another issue where opensips issue a warning I'm trying to load a uuid 
from a postgres database as opensips doesn't have a built-in function to 
generate a uuid. How do I get rid of this warning ? 
  
  WARNING:db_postgres:db_postgres_get_columns: unhandled data type column 
(uuid_generate_v1mc) type id (2950), use DB_STRING as default
  
  Its caused by following line in my config 
  avp_db_query("SELECT uuid_generate_v1mc()","$avp(callid)"); 
  
  does this mean I need to convert it to string before returning from postgres 
via the sql I use ? 
   
  
 _______________________________________________
Users mailing list
Users@lists.opensips.org
http://lists.opensips.org/cgi-bin/mailman/listinfo/users
 
 
 

   
_______________________________________________
Users mailing list
Users@lists.opensips.org
http://lists.opensips.org/cgi-bin/mailman/listinfo/users

Reply via email to