Hi Ben,

The paragraph you refer to is this one :

      o  After having sent or received an answer to the first offer, the
         UAC MAY generate subsequent offers in requests based on rules
         specified for that method, but only if it has received answers
         to any previous offers, and has not sent any offers to which it
         hasn't gotten an answer.


So the 200 must contain the same SDP as the 180 because there is no SDP replied back between the 180 and 200 ?

Regards,

Bogdan-Andrei Iancu

OpenSIPS Founder and Developer
  https://www.opensips-solutions.com
OpenSIPS eBootcamp 2021
  https://opensips.org/training/OpenSIPS_eBootcamp_2021/

On 10/1/21 5:41 PM, Ben Newlin wrote:

No, this is not allowed by the specification, though some devices do handle it.

https://datatracker.ietf.org/doc/html/rfc3261#section-13.2.1 <https://datatracker.ietf.org/doc/html/rfc3261#section-13.2.1>

Ben Newlin

*From: *Users <[email protected]> on behalf of johan <[email protected]>
*Date: *Friday, October 1, 2021 at 10:35 AM
*To: *OpenSIPS users mailling list <[email protected]>
*Subject: *[OpenSIPS-Users] question on call handling.

Dears,


this is more a general sip question.  when establishing a dialog is it
then allowed to change the sdp that you have sent in 183 to somehting
else in 200 Ok ?


wkr,


_______________________________________________
Users mailing list
[email protected]
http://lists.opensips.org/cgi-bin/mailman/listinfo/users <http://lists.opensips.org/cgi-bin/mailman/listinfo/users>


_______________________________________________
Users mailing list
[email protected]
http://lists.opensips.org/cgi-bin/mailman/listinfo/users

_______________________________________________
Users mailing list
[email protected]
http://lists.opensips.org/cgi-bin/mailman/listinfo/users

Reply via email to