Hi,
via the socket_xx() vars you can get only the sockets relative to/used
by that call, you cannot iterate thru the listening sockets.
Regards,
Bogdan-Andrei Iancu
OpenSIPS Founder and Developer
https://www.opensips-solutions.com
OpenSIPS eBootcamp 2021
https://opensips.org/training/OpenSIPS_eBootcamp_2021/
On 11/15/21 9:39 AM, Muhamad Putra Abdullah wrote:
Hi,
I have 2 listening interface for opensips 3.2. How do I get both IP
address to be used as variable in opensips config file? I try to use
socket_in/ socket_out but failed to get the other interface IP address.
Thanks
Sent from Mail <https://go.microsoft.com/fwlink/?LinkId=550986> for
Windows
_______________________________________________
Users mailing list
[email protected]
http://lists.opensips.org/cgi-bin/mailman/listinfo/users
_______________________________________________
Users mailing list
[email protected]
http://lists.opensips.org/cgi-bin/mailman/listinfo/users