An alternative method is to use m4 to feed in the detected IP address into a templated version of the opensips config file.
On Wed, 17 Nov 2021, 08:23 Muhamad Putra Abdullah, <[email protected]> wrote: > Hi, > > > > socket=udp:enp1s0:5060 tag INTERNAL_IP # CUSTOMIZE ME > > socket=udp:enp2s0:5060 tag EXTERNAL_IP # CUSTOMIZE ME > > > > My INTERNAL_IP is set to static and EXTERNAL_IP set to DHCP. I just use > tag to test something. > > > > Regards > > > > *From:* Bogdan-Andrei Iancu <[email protected]> > *Sent:* Wednesday, 17 November, 2021 3:55 PM > *To:* Muhamad Putra Abdullah <[email protected]>; OpenSIPS users > mailling list <[email protected]> > *Subject:* Re: [OpenSIPS-Users] How to get all listening socket IP > address as variable > > > > Hi, > > How do you define the listening socket in OpenSIPs cfg ? (the one related > to the DHCP interface) > > Regards, > > Bogdan-Andrei Iancu > > > > OpenSIPS Founder and Developer > > https://www.opensips-solutions.com > > OpenSIPS eBootcamp 2021 > > https://opensips.org/training/OpenSIPS_eBootcamp_2021/ > > On 11/17/21 2:19 AM, Muhamad Putra Abdullah wrote: > > Hi, > > > > Is there a way to get the IP address of DHCP interface to use in the > script? I can get the call go through if I set both the interface as static. > > > > Regards > > > > Get Outlook for Android <https://aka.ms/AAb9ysg> > > > ------------------------------ > > *From:* Bogdan-Andrei Iancu <[email protected]> <[email protected]> > *Sent:* Tuesday, November 16, 2021, 6:45 PM > *To:* OpenSIPS users mailling list; Muhamad Putra Abdullah > *Subject:* Re: [OpenSIPS-Users] How to get all listening socket IP > address as variable > > > Hi, > > via the socket_xx() vars you can get only the sockets relative to/used by > that call, you cannot iterate thru the listening sockets. > > Regards, > > Bogdan-Andrei Iancu > > > > OpenSIPS Founder and Developer > > https://www.opensips-solutions.com > > OpenSIPS eBootcamp 2021 > > https://opensips.org/training/OpenSIPS_eBootcamp_2021/ > > On 11/15/21 9:39 AM, Muhamad Putra Abdullah wrote: > > Hi, > > > > I have 2 listening interface for opensips 3.2. How do I get both IP > address to be used as variable in opensips config file? I try to use > socket_in/ socket_out but failed to get the other interface IP address. > > > > Thanks > > > > Sent from Mail <https://go.microsoft.com/fwlink/?LinkId=550986> for > Windows > > > > > > _______________________________________________ > > Users mailing list > > [email protected] > > http://lists.opensips.org/cgi-bin/mailman/listinfo/users > > > > > _______________________________________________ > Users mailing list > [email protected] > http://lists.opensips.org/cgi-bin/mailman/listinfo/users >
_______________________________________________ Users mailing list [email protected] http://lists.opensips.org/cgi-bin/mailman/listinfo/users