An alternative method is to use m4 to feed in the detected IP address into
a templated version of the opensips config file.



On Wed, 17 Nov 2021, 08:23 Muhamad Putra Abdullah, <[email protected]>
wrote:

> Hi,
>
>
>
> socket=udp:enp1s0:5060 tag INTERNAL_IP  # CUSTOMIZE ME
>
> socket=udp:enp2s0:5060 tag EXTERNAL_IP  # CUSTOMIZE ME
>
>
>
> My INTERNAL_IP is set to static and EXTERNAL_IP set to DHCP. I just use
> tag to test something.
>
>
>
> Regards
>
>
>
> *From:* Bogdan-Andrei Iancu <[email protected]>
> *Sent:* Wednesday, 17 November, 2021 3:55 PM
> *To:* Muhamad Putra Abdullah <[email protected]>; OpenSIPS users
> mailling list <[email protected]>
> *Subject:* Re: [OpenSIPS-Users] How to get all listening socket IP
> address as variable
>
>
>
> Hi,
>
> How do you define the listening socket in OpenSIPs cfg ? (the one related
> to the DHCP interface)
>
> Regards,
>
> Bogdan-Andrei Iancu
>
>
>
> OpenSIPS Founder and Developer
>
>   https://www.opensips-solutions.com
>
> OpenSIPS eBootcamp 2021
>
>   https://opensips.org/training/OpenSIPS_eBootcamp_2021/
>
> On 11/17/21 2:19 AM, Muhamad Putra Abdullah wrote:
>
> Hi,
>
>
>
> Is there a way to get the IP address of DHCP interface to use in the
> script? I can get the call go through if I set both the interface as static.
>
>
>
> Regards
>
>
>
> Get Outlook for Android <https://aka.ms/AAb9ysg>
>
>
> ------------------------------
>
> *From:* Bogdan-Andrei Iancu <[email protected]> <[email protected]>
> *Sent:* Tuesday, November 16, 2021, 6:45 PM
> *To:* OpenSIPS users mailling list; Muhamad Putra Abdullah
> *Subject:* Re: [OpenSIPS-Users] How to get all listening socket IP
> address as variable
>
>
> Hi,
>
> via the socket_xx() vars you can get only the sockets relative to/used by
> that call, you cannot iterate thru the listening sockets.
>
> Regards,
>
> Bogdan-Andrei Iancu
>
>
>
> OpenSIPS Founder and Developer
>
>   https://www.opensips-solutions.com
>
> OpenSIPS eBootcamp 2021
>
>   https://opensips.org/training/OpenSIPS_eBootcamp_2021/
>
> On 11/15/21 9:39 AM, Muhamad Putra Abdullah wrote:
>
> Hi,
>
>
>
> I have 2 listening interface for opensips 3.2. How do I get both IP
> address to be used as variable in opensips config file? I try to use
> socket_in/ socket_out but failed to get the other interface IP address.
>
>
>
> Thanks
>
>
>
> Sent from Mail <https://go.microsoft.com/fwlink/?LinkId=550986> for
> Windows
>
>
>
>
>
> _______________________________________________
>
> Users mailing list
>
> [email protected]
>
> http://lists.opensips.org/cgi-bin/mailman/listinfo/users
>
>
>
>
> _______________________________________________
> Users mailing list
> [email protected]
> http://lists.opensips.org/cgi-bin/mailman/listinfo/users
>
_______________________________________________
Users mailing list
[email protected]
http://lists.opensips.org/cgi-bin/mailman/listinfo/users

Reply via email to