But I mentioned a problem with using a very dense k - point grid and an 8
atom Si cell, the program exits before it can output the forces, stresses,
and the individual contributions to the total energy (hence why regardless
of what screening parameter I used I got the same band gap, as the fock).
Nobody was able to point me in the right direction with that. Also, another
user has previously reported that using a 2 atom si cell results in an
oscillation in the total energy as you increase ecutwfc (something I have
also verified), so I'm not sure I can accurately calculate the band gap
using a 2 atom cell either.

Phil

On 11 November 2015 at 12:18, Ref Fymz <[email protected]> wrote:

> Hey,
>
> Thanks for the reply. So if I use an 8 atom Si cell, and use fixed
> occupations with 32 bands, the difference between the highest occupied and
> lowest unoccupied is my actual band gap? (i.e the one I can compare to PBE
> and experiment)
>
>
> Phil
>
> On 11 November 2015 at 10:13, Ref Fymz <[email protected]> wrote:
>
>> Hey,
>>
>> I've tried searching the forum, and I haven't come across a way to
>> calculate the band gap in a material using the hybrid functionals. I know
>> you can't do nscf calculations, but is there any simple way to calculate
>> the band gap for a material using scf simulations?
>>
>> Thanks,
>>
>> Phil
>>
>
>
_______________________________________________
Pw_forum mailing list
[email protected]
http://pwscf.org/mailman/listinfo/pw_forum

Reply via email to