Dear QE experts,
I have another two questions from the reply. May be these are very trivial
but as a beginner I am unable to understand these things.
1. *tot_magnetization works with fixed occupation. *So to use
tot_magnetization card one have to use none but fixed occupation. But in
manual it says fixed occupation works with insulator with a band gap, while
my system is metallic (Heusler system). So what to do in my case?
2. To achieve a reasonable tot_magnetization I have to minimize the total
energy value?
Thanking you in advance,
Sayan Chaudhuri
Research Scholar
IIT Indore
On Mon, Jul 3, 2017 at 9:23 AM, sayan chaudhuri <[email protected]> wrote:
> Dear Mostafa Youssef,
>
> Thanks a lot for the apt explanation.
>
> Sayan Chaudhuri
>
> On Sun, Jul 2, 2017 at 8:27 PM, Mostafa Youssef <[email protected]> wrote:
>
>> Dear Sayan,
>>
>>
>> 1- nspin=2 works whether you use LDA or GGA.
>>
>> 2- start_magnetization works when you apply smearing (occupation tag).
>> Using this tag you give an initial guess and let the code to find the final
>> magnetization associated with some nearby local energy minimum.
>> tot_magnetization works with fixed occupation. Here you ask the code to
>> maintain the overall magnetization you specified. There is no guarantee
>> that this will lead to the ground state. But it is useful to do many
>> simulations each with certain total magnetization and compare their final
>> energies.
>>
>> You can learn a lot about the practical aspects of these tags/key words
>> by going over the examples of pw.x and previous forum posts.
>>
>> Regards,
>> Mostafa
>> AUC / MIT
>>
>> _______________________________________________
>> Pw_forum mailing list
>> [email protected]
>> http://pwscf.org/mailman/listinfo/pw_forum
>>
>
>
_______________________________________________
Pw_forum mailing list
[email protected]
http://pwscf.org/mailman/listinfo/pw_forum