Dear Sayan, In the case of metallic systems, it is recommended to use smearing. With the smearing applied, you can use start_magnetization to give an initial guess for the magnetic moment. pw.x will try self-consistently to find the final magnetization that leads to minimum energy (Achieving both goals simultaneously). No need for the tot_magnetization in this case.
Regards, Mostafa