Dear Sayan,

In the case of metallic systems, it is recommended to use smearing. With the 
smearing applied, you can use start_magnetization to give an initial guess for 
the magnetic moment.  pw.x will try self-consistently to find the final 
magnetization that leads to minimum energy (Achieving both goals 
simultaneously).  No need for the tot_magnetization in this case.


Regards,
Mostafa