I tested with GenerateFlowFile. Even when I could see the link pointing to the production properties file, it was still holding that value. Weird part is I changed the test environment's value to a nonsense URL and it didn't pick that up. I'll keep looking.
So you're sure that it's not stored anywhere? Thanks, Mike On Sun, Dec 17, 2017 at 6:14 PM, Joe Witt <[email protected]> wrote: > dropped dev list. please post to one or the other for these. > > The values arent stored so if the same values exist after restart id > suspect an issue with the link. > > you could test this with a custom proc for example > > On Dec 17, 2017 5:47 PM, "Mike Thomsen" <[email protected]> wrote: > >> I have a variable registry set up with a view environment-specific >> variables. I use a symlink to switch between properties files when I need >> NiFi to target one environment vs the other. After restarting NiFi, I >> noticed that it hasn't actually changed the variables. The ones for the >> test environment are still in there despite me changing the symlink to >> point to the prod environment and a restart. >> >> Am I doing something wrong or is this a bug? >> >> Thanks, >> >> Mike >> >