Any error/message in nifi-app or nifi-user log files? Le lun. 19 juil. 2021 à 18:32, <[email protected]> a écrit :
> Yes, data has been going through the components for at least two weeks on > one instance and a few hours on the other. > Same message on both systems for all components. > > Thanks, > Matt > > > --------- Original Message --------- > Subject: Re: Insufficient history, please try again later > From: "Pierre Villard" <[email protected]> > Date: 7/19/21 12:07 pm > To: "[email protected]" <[email protected]> > > Hi, > > You usually need to wait a few minutes after some data went through the > component to get something to display. > Are you experiencing this issue after a while even though data is going > through the component? > Please keep in mind that stats are removed after a restart when using the > volatile repository. > > Thanks, > Pierre > > Le lun. 19 juil. 2021 à 17:30, <[email protected]> a écrit : > >> I am running NiFi 1.13.2 on Windows 2012 Server. >> For any of my process blocks if I try to look at "Status History" I get a >> dialog "Insufficient history, please try again later." >> >> I *think* that these settings should provide me with *some* history but >> it very well be that I am mistaken and have things configured incorrectly. >> >> >> nifi.components.status.repository.implementation=org.apache.nifi.controller.status.history.VolatileComponentStatusRepository >> nifi.components.status.repository.buffer.size=1440 >> nifi.components.status.snapshot.frequency=1 min >> >> What am I doing wrong here? >> >> Thanks, >> Matt >> >