Hmmm, I'm beginning to suspect the LSI MegaRaid chips. I replaced the SSD of the first node with a brand new Samsung 256GB SSD and the second node with a 1TB HDD.
When I change the SWAP size on both nodes to 4GB, it fails to install the bootloader. When I leave everything on default and just continue the steps, I get an "error 30 read-only filesystem" on BOTH nodes. When I choose Other drive and select /dev/sda, I get the ValueError exception. So I'm kinda stuck :-& Our RAID chip is LSI 2108 SAS Kind regards, Jorick Astrego -----Original Message----- > From: "Jorick Astrego" <[email protected]> > To: "Fabian Deutsch" <[email protected]> > Cc: [email protected] > Date: 19/09/2013 12:53 > Subject: Re: [Users] Exception: ValueError("invalid literal for int() with > base 10: ' '", ) > > Hi, > > I'm using ovirt-node-iso-3.0.1-1.0.2.vdsm.fc19.iso and I tried reproducing on > two nodes. I thought maybe the first node's SSD had failed. > > See screenshots attached (they are very small). > > As the Local disk first only reported 1GB, i used Other device /dev/sda and > got the ValueError (xxx_144.png). > > When using Local disk, I get a 'Read-only file system' error. (xxx_145.png) > > This is on two identical nodes with a SSD connected through LSI MegaRAID. I > could try it without RAID, but I'll have to visit the datacenter and reflash > the LSI firmware for this. > > Both nodes had an older 2.6 node image running on it before. > > After a full RAID re-initialization that produced no errors, I now get yet > another faillure: > > "Exception: RuntimeError('Failed to set install bootloader'.)" (xxx_147.png) > > Can it be the SSD or RAID controller? I could swap out the SSD for a 2.5 hdd > to test it out. > > Thanks in advance! > > Jorick Astrego > Netbulae B.V. > > > -----Original Message----- > > From: "Fabian Deutsch" <[email protected]> > > To: "Jorick Astrego" <[email protected]> > > Cc: [email protected] > > Date: 18/09/2013 15:49 > > Subject: Re: [Users] Exception: ValueError("invalid literal for int() with > > base 10: ' '", ) > > > > Hey, > > > > Am Mittwoch, den 18.09.2013, 15:35 +0200 schrieb Jorick Astrego: > > > I'm trying to deploy the ovirt node 3.0.1-1.0.2 image. Because we only > > > have a small SSD and don't need overcommit I changed the swap file size > > > to a smaller value. > > > > > > While installing I now get the following error and have to reboot: > > > > > > Exception: ValueError("invalid literal for int() with base 10: ' '",) > > > > I tried to reproduce this problem but couldn't trigger it using: > > 1. Enter the storage sizes page > > 2. Changed the swap value to 100 (allowed value depends on your hosts > > mem size) > > 3. Saved page, went through the next pages and installed > > > > Could you explain in detail how you triggered this problem? > > And are you using the fc19 or el6 iso? > > > > Greetings > > fabian > > > > > > > If I don't change the value of the swap, I get a message that the > > > installer is unable to format/partition the disk. > > > > > > Kind regards, > > > > > > Jorick Astrego > > > > > > > > > > > > > > > _______________________________________________ > > > Users mailing list > > > [email protected] > > > http://lists.ovirt.org/mailman/listinfo/users > > > _______________________________________________ > Users mailing list > [email protected] > http://lists.ovirt.org/mailman/listinfo/users > _______________________________________________ Users mailing list [email protected] http://lists.ovirt.org/mailman/listinfo/users

