Hello, 

In our oVirt hosts, we are using DELL equallogic SAN with each server 
connecting to SAN via 2 physical interfaces. Since both interfaces share the 
same network (Equalogic limitation) we must patch the linux kernel to to allow 
iSCSI multipath with multiple NICs in the same subnet with sysctl : 

--------------------------------------------------------------------------------------------
 
net.ipv4.conf.p2p1.arp_ignore=1
net.ipv4.conf.p2p1.arp_announce=2
net.ipv4.conf.p2p1.rp_filter=2

net.ipv4.conf.p2p2.arp_ignore=1
net.ipv4.conf.p2p2.arp_announce=2
net.ipv4.conf.p2p2.rp_filter=2 



--------------------------------------------------------------------------------------------
 



This works great in most setups, but for a strange reason, on some of our 
setups, the sysctl configuration is updated by VDSM when activating a host and 
the second interface stops working immeadiatly : 
--------------------------------------------------------------------------------------------
 
vdsm.log 
2017-06-07 11:51:51,063+0200 INFO  (jsonrpc/5) [storage.ISCSI] Setting strict 
mode rp_filter for device 'p2p2'. (iscsi:602)
2017-06-07 11:51:51,064+0200 ERROR (jsonrpc/5) [storage.HSM] Could not connect 
to storageServer (hsm:2392)
Traceback (most recent call last):
  File "/usr/share/vdsm/storage/hsm.py", line 2389, in connectStorageServer
    conObj.connect()
  File "/usr/share/vdsm/storage/storageServer.py", line 433, in connect
    iscsi.addIscsiNode(self._iface, self._target, self._cred)
  File "/usr/lib/python2.7/site-packages/vdsm/storage/iscsi.py", line 232, in 
addIscsiNode
    iscsiadm.node_login(iface.name, target.address, target.iqn)
  File "/usr/lib/python2.7/site-packages/vdsm/storage/iscsiadm.py", line 337, 
in node_login
    raise IscsiNodeError(rc, out, err) 




--------------------------------------------------------------------------------------------
 

"strict mode" is enforced for second interface, and it no longuer works... 
Which means - at least - that there is no redundancy in case of hardware 
faillure and this is not acceptable for our production needs. 

What is really strange is that we have another "twin" site on another 
geographic region with simillar hardware configuration and same oVirt 
installation, and this problem does not happen. 

What can be the root cause of this behaviour? How can I correct it? 

our setup: 
hostedEngine : Centor 7.3, ovirt 4.1.2 
3 physical nodes centos 7.3, ovirt 4.1.2 
SAN DELL Equalogic 

cordialement, regards, 


        Nelson LAMEIRAS 
Ingénieur Systèmes et Réseaux / Systems and Networks engineer 