I usually look at IOPs using IOMeter… you usually want several workers running 
reads and writes in different threads at the same time.   You can run Dynamo on 
a Linux instance and then connect it to a window GUI running IOMeter to give 
you stats.  I was getting around 250 IOPs on JBOD sata 7200rpm drives which 
isn’t bad for cheap and cheerful sata drives.

 

As I said, I’ve worked with HCI in VMware now for a couple of years, intensely 
this last year when we had some defective Dell hardware and trying to diagnose 
the problem.  Since then the hardware has been completely replaced with all 
flash solution.   So when I got the all flash solution I used IOmeter on it and 
was only getting around 3000 IOPs on enterprise flash disks… not exactly 
stellar, but OK for one VM.  The trick there was the scale out.  There is a 
VMware Fling call HCI Bench.  Its very cool in that you spin up one VM and then 
it spawns 40 more VMs across the cluster.  I  could then use VSAN observer and 
it showed my hosts were actually doing 30K IOPs on average which is absolutely 
stellar performance.  

 

Anyway, moral of the story there was that your one VM may seem like its quick, 
but not what you would expect from flash…   but as you add more VMs in the 
cluster and they are all doing workloads, it scales out beautifully and the 
read/write speed does not slow down as you add more loads.  I’m hoping that’s 
what we are going to see with Gluster.

 

Also, you are using mb nomenclature below, is that Mb, or MB?  I am sort of 
assuming MB megabytes per second…  it does not seem very fast.  I’m probably 
not going to get to work more on my cluster today as I’ve got other projects 
that I need to get done on time, but I want to try and get some templates up 
and running and do some more testing either tomorrow or this weekend and see 
what I get in just basic writing MB/s and let you know.

 

Regards

Bill

 

 

From: Jayme <jay...@gmail.com> 
Sent: Thursday, August 2, 2018 8:12 AM
To: users <users@ovirt.org>
Subject: [ovirt-users] Tuning and testing GlusterFS performance

 

So I've finally completed my first HCI build using the below configuration:

 

3x

Dell PowerEdge R720

2x 2.9 GHz 8 Core E5-2690

256GB RAM

2x250gb SSD Raid 1 (boot/os)

2x2TB SSD jbod passthrough (used for gluster bricks)

1Gbe Nic for management 10Gbe nic for Gluster

 

Using Replica 3 with no arbiter. 

 

Installed the latest version of oVirt available at the time 4.2.5.  Created 
recommended volumes (with an additional data volume on second SSD). Not using 
VDO

 

First thing I did was setup glusterFS network on 10Gbe and set it to be used 
for glusterFS and migration traffic. 

 

I've setup a single test VM using Centos7 minimal on the default "x-large 
instance" profile. 

 

Within this VM if I do very basic write test using something like:

 

dd bs=1M count=256 if=/dev/zero of=test conv=fdatasync

 

I'm seeing quite slow speeds, only 8mb/sec.  

 

If I do the same from one of the hosts gluster mounts i.e.

 

host1: /rhev/data-center/mnt/glusterSD/HOST:data 

 

I get about 30mb/sec (which still seems fairly low?)

 

Am I testing incorrectly here?  Is there anything I should be tuning on the 
Gluster volumes to increase performance with SSDs?  Where can I find out where 
the bottle neck is here, or is this expected performance of Gluster? 

_______________________________________________
Users mailing list -- users@ovirt.org
To unsubscribe send an email to users-le...@ovirt.org
Privacy Statement: https://www.ovirt.org/site/privacy-policy/
oVirt Code of Conduct: 
https://www.ovirt.org/community/about/community-guidelines/
List Archives: 
https://lists.ovirt.org/archives/list/users@ovirt.org/message/YL4O7LQKXG6WTJGEW6GDNAL7RPULTZAW/