Dear John,

I noticed the closeness of 2.52 inches and 64 mm and then I wondered whether they were trying to fit a metric cable into an old- pre-metric space or vice-versa.

On another issue from the same article, I wondered about where in Italy you could buy a 2 inch cable. This would be a most unusual size in Italy and would have to be a special order as I don't think any Italian cable maker would routinely make products to inch sizes.

Cheers,

Pat Naughtin
Author of the forthcoming book, Metrication Leaders Guide.
PO Box 305 Belmont 3216,
Geelong, Australia
Phone: 61 3 5241 2008

Metric system consultant, writer, and speaker, Pat Naughtin, has helped thousands of people and hundreds of companies upgrade to the modern metric system smoothly, quickly, and so economically that they now save thousands each year when buying, processing, or selling for their businesses. Pat provides services and resources for many different trades, crafts, and professions for commercial, industrial and government metrication leaders in Asia, Europe, and in the USA. Pat's clients include the Australian Government, Google, NASA, NIST, and the metric associations of Canada, the UK, and the USA. See http://www.metricationmatters.com for more metrication information, contact Pat at [email protected] or to get the free 'Metrication matters' newsletter go to: http://www.metricationmatters.com/newsletter to subscribe.

On 2009/08/06, at 4:32 PM, John Frewen-Lord wrote:

As a surveyor in the construction industry (and having worked in both imperial and metric in the UK, the US, Canada and South Africa), something about this story doesn't quite ring true.

1. In-the-field tolerances are never less than 1/16" imperial (1.6 mm), or 1 mm metric (at least I've never come across tolerances tighter than that, and that includes a lot of precision hospital work). The 2/100ths of an inch is almost exactly 0.5 mm, a tolerance virtually impossible to achieve on a construction site.

2. The 2.52" is almost exactly 64 mm. Allowing for a tolerance of say +/- 1 mm, the trench should have been specified at 65 mm.

3. I'm no electrical expert, but I do know that cables when conducting electricity heat up and expand. Was no allowance made for this? And would it not have been wise to allow a tiny bit of airpace between the cable and trench walls to allow air circulation and help the cable to stay cool(er)?

I wonder if there's more to this story than is being told?

Cheers

John F-L