Dear Amirhosein! the time synchronization methods mentioned in http://files.ettus.com/manual/page_sync.html solve that: it doesn't matter when you put the data on Ethernet, the USRP will send it when the time set for transmission is reached.
Best regards, Marcus On Tue, 2018-06-12 at 09:27 +0000, Amirhosein naseri via USRP-users wrote: > Hello everybody > > How can i solve transmit latency over Ethernet in USRP N210 for > timestamped bursts?? > As u know amount of this latency is not constant and change over time > ... > > Tnx. > _______________________________________________ > USRP-users mailing list > [email protected] > http://lists.ettus.com/mailman/listinfo/usrp-users_lists.ettus.com _______________________________________________ USRP-users mailing list [email protected] http://lists.ettus.com/mailman/listinfo/usrp-users_lists.ettus.com