On 09/07/2018 04:32 PM, Serge Malo via USRP-users wrote:
Hi all,
I'm trying to use 2 different sampling rates the 2 TX channels of a X300.
Basically, I create 2 different tx_streamers, and call
usrp->set_tx_rate() for each channel.
I'm getting this error from UHD:
Multiple sampling rates downstream of TX Terminator 0: RuntimeError:
Node 0/DUC_0 specifies 1.25e+07, node 0/DUC_1 specifies 2.5e+07.
I'm using UHD 3.10.3.0.
Can you tell me if this is expected, or should I be able to use 2
different sampling rates?
Thanks,
Serge
If you want different sample rates, you'll likely need to create two
independent multi_usrp objects to contain the streamers.
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
- - - - - - - - - - - - - - -
*Meet us at ION GNSS+ 2018 in Miami! Sept 24-28 2018, booth 604.*