Yes to both!. That's what led me to believe the rate was wrong. LFRX is DC coupled, but the arrangement it's in has the next component in the chain blocking DC.
I tested with gr-ettus/device3 today, and the bug isn't there. So I think there's something in the legacy driver. Nick On Sat, Jun 15, 2019 at 11:03 AM Ian Buckley <[email protected]> wrote: > Go tune WWV, your friendly Federal signal generator? > (Also isn’t LFRX DC coupled?) > > > On Jun 14, 2019, at 11:43 PM, Nick Foster via USRP-users < > [email protected]> wrote: > > > > Got a weird one here. I'm using an X310 with UHD 3.14.0.0-87-g4e084337, > with two LFRX daughterboards installed. Legacy interface with gr-uhd, not > gr-ettus, just testing things in the field. When I tune to 15MHz sample > rate at 1Msps, I get a resulting stream that looks for all the world like > it's coming in at 7.5MHz and 500ksps. Because this is a field deployment, > and because I don't have immediate access to a signal generator, it's a bit > hard to confirm that. It looks to me (at first blush) like the DDC block is > getting an incorrect master clock rate, and setting its tick rate > accordingly. When I set the frequency to 30MHz and the sample rate to > 2Msps, I get the result I'm expecting. > > > > I don't believe I'm seeing the same problem with device3/gr-ettus, but > I'll test that further today. Anyone seen behavior like this before? > There's also an unexpected DC offset I haven't seen before, if that helps > jog anyone's memory. Since it's direct-sampled, not zero-IF, any DC offset > must be the result of the DSP chain. > > > > Nick > > _______________________________________________ > > USRP-users mailing list > > [email protected] > > http://lists.ettus.com/mailman/listinfo/usrp-users_lists.ettus.com > >
_______________________________________________ USRP-users mailing list [email protected] http://lists.ettus.com/mailman/listinfo/usrp-users_lists.ettus.com