On 02/23/2021 03:45 AM, COURANT Frederique - Contractor wrote:

I’m working in python.

*De :*COURANT Frederique - Contractor
*Envoyé :* mardi 23 février 2021 09:13
*À :* 'Marcus D Leech' <[email protected]>
*Objet :* RE: [USRP-users] Read a register

My USRP platform is the X310.

I would like to read an internal control register at the address 133. I had ever allocated in the xml file with the name status.


From the fact that you've mentioned XML, I'm going to *guess* that you're working with RFNOC, and thus the "radio3" API.

I'm pretty sure that in the regular multi_usrp API, the python interface doesn't expose low-level register I/O, but the story may be different in RFNOC--so at this point I'm hoping an RFNOC person can jump in, but a lot more context will be needed.


_______________________________________________
USRP-users mailing list
[email protected]
http://lists.ettus.com/mailman/listinfo/usrp-users_lists.ettus.com

Reply via email to