What software are you using for the capture? Custom C++?  gnuradio?

On Wed, Nov 17, 2021 at 4:04 AM 陈煜 <[email protected]> wrote:

> hello,
>
>   I use four usrp-2945 as synchronous acquisition system, CDA-2990
> provides internal reference clock and PPS to four usrp-2945, and pxie-5651
> and pxie-5652 are used to provide two-stage local oscillator for four
> USRPs. Now I use two usrp-2945 to collect the data of two channels (one
> channel for each) and calculate the phase difference between the two
> channels. If I use UHD 4.1.0.1, after multiple acquisition, I find that
> there are four kinds of phase differences, and the phase differences are
> roughly 90 degrees, 180 degrees and 270 degrees. For example, the four
> phase differences are 4.5 degrees, 95.53 degrees, 189.51 degrees and 275.49
> degrees respectively. If I use UHD 3.15.0.0, there is only one phase
> difference.
>
> Setup Details
> 1.CDA-2990 provides internal reference clock and PPS to four usrps.
> 2.Pxie-5651 and Pxie-5652 are used to provide two-stage local oscillator
> for four USRPs.
>
> Expected Behavior
> Using UHD 4.1.0.1, there is only one phase difference.
>
> Actual Behaviour
> There are four phase differences using UHD 4.1.0.1.
>
> Steps to reproduce the problem
> After synchronizing the reference clock, PPS and lo, use UHD 4.1.0.1 to
> collect one channel of different USRP and calculate the phase difference.
>
> can anybody help me?
> _______________________________________________
> USRP-users mailing list -- [email protected]
> To unsubscribe send an email to [email protected]
>
_______________________________________________
USRP-users mailing list -- [email protected]
To unsubscribe send an email to [email protected]

Reply via email to