Hello, When I work with 1 B210 I can get 2 Rx perfectly synchronized as expected. Also, if I use 2 B210 with 1 Rx each, I can synchronize them with an external reference (in this case the octoclock) without any problem. However, when using 2 B210 with 2 Rx each (4 Rx in total) the synchronization is still perfect between Rx of the same devices, but has some problems between Rx of different devices. Of course, the result with the octoclock is way better than if I do not use any external reference. Nevertheless, it seems that there are some problems with the phase sync (although the frequency sync seems correct). I wonder if this is a hardware limitation or if there is something I am not doing right.
Thank you very much, Álvaro