NON CLASSIFIÉ / UNCLASSIFIED

I am putting together a parts list for a test station, and I am currently 
planning the reference clock distribution scheme. What is the minimum power for 
the B210 10 MHz reference clock input? The knowledge base indicates +15 dBm 
maximum, but provides no minimum: 
https://files.ettus.com/manual/page_usrp_b200.html

I was planning on distributing a 0 dBm sinusoidal 10 MHz reference clock to all 
the test equipment. Any problems with this approach with a B210?

-Peter
_______________________________________________
USRP-users mailing list -- usrp-users@lists.ettus.com
To unsubscribe send an email to usrp-users-le...@lists.ettus.com

Reply via email to