On 2025-08-12 16:27, Kazakoff, Peter (ASC/CSA) wrote:
NON CLASSIFIÉ / UNCLASSIFIED
I am putting together a parts list for a test station, and I am currently
planning the reference clock distribution scheme. What is the minimum power for
the B210 10 MHz reference clock input? The knowledge base indicates +15 dBm
maximum, but provides no minimum:
https://files.ettus.com/manual/page_usrp_b200.html
I was planning on distributing a 0 dBm sinusoidal 10 MHz reference clock to all
the test equipment. Any problems with this approach with a B210?
-Peter
_______________________________________________
USRP-users mailing list -- usrp-users@lists.ettus.com
To unsubscribe send an email to usrp-users-le...@lists.ettus.com
The data sheet for the PLL that is driven by the REF clock input says
-5dBm minimum. My guess is that if your distributor is able to deliver
0dBm on all ports, it should be fine.
_______________________________________________
USRP-users mailing list -- usrp-users@lists.ettus.com
To unsubscribe send an email to usrp-users-le...@lists.ettus.com