https://codereview.chromium.org/13950013/diff/3001/src/hydrogen.cc
File src/hydrogen.cc (right):
https://codereview.chromium.org/13950013/diff/3001/src/hydrogen.cc#newcode3745
src/hydrogen.cc:3745: worklist.Add(phi, zone());
Thanks for the review.
It seems that we do not need BitVector for this special case as the
worklist only contains PHIs which might be truncated to int32 (the
assumption in the beginning) but could not be truncated as there is a
non-truncating int32 or a double usage in the first iteration, and a
non-truncating PHI usage in the following worklist iterations. So there
is only one state change for the PHI and a PHI will never be added to
the worklist twice.