on 11/21/00 9:32 AM, Dan Weeks at [EMAIL PROTECTED] wrote:

> Yeah, 2800 btus is about half of what a 1500 watt electric heater puts out,
> and that's not much at all. I'm trying to insulate my 26 footer to the point
> where I can heat it with the 5200 btus my little 1500 watt ceramic heater
> puts out, and it's going to be a challenge. CAUTION!!!! I don't know what kind
of AS you have, but if it is of the 60-70's vintage, Please check your
wiring to be sure it is not aluminum... I have a '68 Caravel & learned to my
chagrin that it is wired in aluminum, which is dangerous for any kind of
load... lots of discussion has been devoted to this subject and there are
some very knowledgable members on this list... if you have copper so much
the better, I just wouldn't like to see a fellow listee get more heat than
they bargained for. James
> 
> 
> 
> 
> To unsubscribe or to change to a daily Digest, please go to
> http://www.airstream.net/vaclist/listoffice.html
> 
> If replying back to this message, please delete all the unnecessary original
> text from your reply.
> 
> 




To unsubscribe or to change to a daily Digest, please go to
http://www.airstream.net/vaclist/listoffice.html

If replying back to this message, please delete all the unnecessary original
text from your reply.

 

Reply via email to