Dennis,
 It could be the "sail switch", a flap that hangs in the blower's
airstream (no pun intended) to "prove" the air flow before allowing the
gas to come on.

It also could be the circuit board. I think that RV Mobile
(http://www.rvmobile.com) sells a generic replacement that's better than
OEM.

                                  <<Jim>>

> Dennis Ober wrote:
> 
>      I have a 86 a/s ....the furnace fan comes on but not the burner
> flame ... do I have to take out the whole furnace to get to the relay
> switch or circuit board ...does any one else have or had this burner
> promblem ...what should I BE LOOKING FOR ??thanks ...keep up the
> digest  ...I read it every day ... only 10 more years till mine is a
> vintage ...... Dennis  "OBIE "

-- 

                       <<http://www.oldengine.org/members/jdunmyer>>
                                <<[EMAIL PROTECTED]>>
                               <<lower SE Michigan, USA>>
                            <<mailto:[EMAIL PROTECTED]>>



To unsubscribe or to change to a daily Digest, please go to
http://www.airstream.net/vaclist/listoffice.html

If replying back to this message, please delete all the unnecessary original
text from your reply.

 

Reply via email to