On 18.12.2008 15:06, Gerald Dachs wrote:
> Hi Hanno,
> 
> Quoting Hanno Zulla <a...@hanno.de>:
> 
>> Hi,
>>
>> what is the timezone of the "next timer" Unixtime/time_t parameter that
>> vdr passes to the shutdown-hooks?
> 
> Not from knowledge but from experience I can say it is localtime. Your
> vdr-addon-acpiwakeup script works only if localtime is UTC and
> /sys/class/rtc/rtc0/wakealarm expects POSIX epoch, so it must be localtime.

>From VDR/INSTALL:

  The command given in the '-s' option will be called with five parameters.

  The first one is the time (in UTC) of the next timer event or plugin wakeup
  time (as a time_t type number), ...


Klaus