Antoni Segura Puimedon has posted comments on this change. Change subject: Sysctl to allow iSCSI multipath with multiple NICs in the same subnet ......................................................................
Patch Set 17: (1 comment) http://gerrit.ovirt.org/#/c/31529/17/vdsm/vdsm-sysctl.conf File vdsm/vdsm-sysctl.conf: Line 9: # For the ARP flux problem, where the machine may respond to ARP requests Line 10: # from all Ethernet interfaces, we are setting "arp_ignore=1" and Line 11: # "arp_announce=2" Line 12: net.ipv4.conf.default.arp_ignore = 1 Line 13: net.ipv4.conf.default.arp_announce = 2 Have you tried this with running more than one VM on the host and making them communicate among themselves and to other machines in the network? -- To view, visit http://gerrit.ovirt.org/31529 To unsubscribe, visit http://gerrit.ovirt.org/settings Gerrit-MessageType: comment Gerrit-Change-Id: Ibf93d49317c76aece764e53e58e0ff28868f16b0 Gerrit-PatchSet: 17 Gerrit-Project: vdsm Gerrit-Branch: master Gerrit-Owner: Amador Pahim <[email protected]> Gerrit-Reviewer: Amador Pahim <[email protected]> Gerrit-Reviewer: Antoni Segura Puimedon <[email protected]> Gerrit-Reviewer: Dan Kenigsberg <[email protected]> Gerrit-Reviewer: Nir Soffer <[email protected]> Gerrit-Reviewer: Sergey Gotliv <[email protected]> Gerrit-Reviewer: [email protected] Gerrit-Reviewer: jian wang <[email protected]> Gerrit-Reviewer: oVirt Jenkins CI Server Gerrit-HasComments: Yes _______________________________________________ vdsm-patches mailing list [email protected] https://lists.fedorahosted.org/mailman/listinfo/vdsm-patches