Hi Anurag,

Here is the configuration guide 
http://australia.emc.com/collateral/software/white-papers/h7296-data-domain-boost-openstorage-wp.pdf

Hope this helps.

Best regards, Mikhail

On 3 Feb 2014, at 6:06 am, Anurag Sharma <sharma.anu...@hotmail.com> wrote:

> Thank you Mikhail for updating me I really appreciate it.
> 
> Suni : Let us know what did you do finally. DDBOOST over IP or FC or VTL over 
> FC ?
> 
> MikhailI hate to say but do you have these documentations pdfs handy if you 
> can email me acrooss ?
> 
> Anurag
> 
> Date: Sat, 1 Feb 2014 21:54:19 +1100
> Subject: RE: [Veritas-bu] Netbackup With Data Domain,
> From: mikhail.niki...@gmail.com
> To: sharma.anu...@hotmail.com
> CC: sunilgulati1...@gmail.com; veritas-bu@mailman.eng.auburn.edu
> 
> Hi Anurag,
> DD Boost over FC utilizes additional DFC storage server responsible for FC 
> transfer, on top those you have for Boost over IP. Also, by design 
> replication between DD boxes runs over IP.
> The workflow is explained in the DD Boost plug-in documentation in details.
> Best regards, Mikhail
> On 01/02/2014 7:38 pm, "Anurag Sharma" <sharma.anu...@hotmail.com> wrote:
> Mikhal,
> 
> I have not checked the latest one so you could be right.
> 
> But explain me this. 
> 
> When you are doing DDBOOST over FC how media server will see DD and Storage 
> Server and that communication would still have to be through IP right ? So I 
> guess you will establish initial connection using mangement IP then transfer 
> data using FC ???
> 
>  
> 
> Anurag 
> 
> Date: Sat, 1 Feb 2014 19:18:46 +1100
> Subject: RE: [Veritas-bu] Netbackup With Data Domain,
> From: mikhail.niki...@gmail.com
> To: sharma.anu...@hotmail.com
> CC: sunilgulati1...@gmail.com; veritas-bu@mailman.eng.auburn.edu
> 
> Anurag,
> This is not correct.
> Several DD models have been qualified by Symantec and EMC for DD Boost over 
> FC on NBU 7.6 and DD OS 5.3+/BOOST plug-in 2.6+
> You may want check NBU HCL and my.datadomain.com if you have missed the 
> announcement from EMC.
> Best regards, Mikhail
> On 01/02/2014 6:39 pm, "Anurag Sharma" <sharma.anu...@hotmail.com> wrote:
> Sunit
> 
> DDBOOST on FC not possible. 
> 
> Do FC if you want VTL deployments.
> 
> DDBOOST works at high speed on 10g network.
> 
> So it depends what you have if you can have 10g connectivity between media 
> servers and DD then go for DDBOOST
> 
> else go fibre with VTL implementation
> 
> Also you can not use one DD device as VTL and DDBOOST at the same time.
> 
> Anurag
> 
> Date: Mon, 27 Jan 2014 23:58:33 +1100
> From: mikhail.niki...@gmail.com
> To: sunilgulati1...@gmail.com
> CC: VERITAS-BU@mailman.eng.auburn.edu
> Subject: Re: [Veritas-bu] Netbackup With Data Domain,
> 
> Hi Sunil,
> I believe you can use DD Boost over FC between media server and DD. With 
> NetWorker you can use ClientDirect with FC, too if memory serves me well.
> However, DDs can't replicate over FC atm, you have to use 1 or 10 gig links 
> to replicate data.
> Of course you need DD OS 5.4+, DD Boost plug-in 2.6+ and NBU 7.6. Don't 
> forget to check your FC infrastructure with EMC for DD Boost over FC 
> compatibility. EMC pre-sales should pass your configuration through a 
> qualification process, in theory.
> Best regards, Mikhail
> On 27/01/2014 8:46 pm, "Sunil Gulati" <sunilgulati1...@gmail.com> wrote:
> Hello,
>  
> Can we use DDboost feature over FC ? Like I have production and a DR site in 
> my environment. I have data domain & netbackup media servers at both 
> location. I have kept tape library at my primary site for tape outs.
>  
> I want to use SLP which will run 4 backup jobs  (Backup, Replication, Import 
> & duplication) means I'll be replicating my backup images from production 
> site to DR site using DDboost.
>  
> I want to know if I can use the same over FC ?
>  
> Thanks
>  
> Sunil
>  
>  
> 
> _______________________________________________
> Veritas-bu maillist  -  Veritas-bu@mailman.eng.auburn.edu
> http://mailman.eng.auburn.edu/mailman/listinfo/veritas-bu
> 
> 
> _______________________________________________ Veritas-bu maillist 
> -veritas...@mailman.eng.auburn.eduhttp://mailman.eng.auburn.edu/mailman/listinfo/veritas-bu

_______________________________________________
Veritas-bu maillist  -  Veritas-bu@mailman.eng.auburn.edu
http://mailman.eng.auburn.edu/mailman/listinfo/veritas-bu

Reply via email to