Hi Nick;
:REGIONS.
*RegionId VolSer RegStart RegEnd Dev-Type Comments
.
.
.
GENT29 GENT29 START END 3390-3
GENT3B GENT3B START END 3390-3
GENT3F GENT3F START END 3390-3
GENT32 GENT32 START END 3390-3
.
.
.
PENG01 PENG01 START END 3390-3
PENG02 PENG02 START END 3390-3
PENG03 PENG03 START END 3390-27
PENG04 PENG04 START END 3390-27
PENG07 PENG07 START END 3390-3
.
.
.
:END.
:DEFAULTS.
* IBM supplied defaults are contained in the DEFAULTS DATADVH file.
* The following are customer overrides and supplements.
*
*DASDType Max-Size
3390-3 3339
3390-9 10017
3390-27 32760
:END.
GENT3B and PENG03 show up in DIRMAP as having 1113 cyl. Everything
Else seems to work properly.
PENG03 later appears in a group definition, but GENT3B does not.
--
Robert P. Nix Mayo Foundation
RO-OC-1-13 (new loc) 200 First Street SW
507-284-0844 Rochester, MN 55905
-----
"In theory, theory and practice are the same, but
in practice, theory and practice are different."
-----Original Message-----
From: VM/ESA and z/VM Discussions [mailto:[EMAIL PROTECTED] On Behalf Of Nick
Laflamme
Sent: Monday, December 12, 2005 1:52 PM
To: [email protected]
Subject: Re: DirMaint Extent Control woes...
Care to show us the relevant lines from EXTENT CONTROL?
Nick