On Wednesday, 01/25/2006 at 07:55 CST, Thomas Kern <[EMAIL PROTECTED]> 
wrote:
> The background for this is that we run a z890 with two LPARs on the CP 
side.
> We have real ESCON CTCs between these two LPARS for GRS between z/OS.e 
and
> z/OS. Both of these z/OS(.e) systems are at the 1.6 level. The z/OS 
system
> is a guest under z/VM 5.1. We have just found out that our Disaster 
Recovery
> vendor does not have any hardware that will support z/OS.e.
> 
> We are looking at the possibility of running two z/OS guests under z/VM 
in a
> single LPAR. We could then use virtual CTCs between these two guests for 
GRS.
> Does z/VM's support/emulation of CTC's allow for "GRS in a ring
> configuration without sysplex"? In the real I/O configuration this 
requires
> BCTC definitions.

z/VM simulates ESCON SCTC, BCTC, and CNC connections.  HELP DEFINE CTCA 
for details.

Alan Altmark
z/VM Development
IBM Endicott