try VMFSETUP ZVM CPSFS
David

Little, Chris wrote:

Yes, maint.
yes, 4.4

And you answered my question.  We are at RSU 0501.  Thank you.  Instead of
begging for answers, I was trying to answer them myself while learning about
the system.

I executed Jim's recommendation for vmfsetup zvm cp and received the
following.  Which answers some questions and raises the following....

vmfsetup zvm cp VMFSET2760I VMFSETUP processing started for ZVM CP DMSACP113S E(2C4) not attached or invalid device address VMFSET1905E The access of 2C4 failed with a return code of 100. DMSACP113S F(2C2) not attached or invalid device address VMFSET1905E The access of 2C2 failed with a return code of 100. DMSACP113S G(2A6) not attached or invalid device address VMFSET1905E The access of 2A6 failed with a return code of 100. DMSACP113S H(2A4) not attached or invalid device address VMFSET1905E The access of 2A4 failed with a return code of 100. DMSACP113S I(2A2) not attached or invalid device address VMFSET1905E The access of 2A2 failed with a return code of 100. DMSACP113S J(2D2) not attached or invalid device address VMFSET1905E The access of 2D2 failed with a return code of 100. DMSACP113S O(194) not attached or invalid device address VMFSET1905E The access of 194 failed with a return code of 100. VMFSET2760I VMFSETUP processing completed unsuccessfully Ready(00012); T=0.06/0.07 15:02:31
-----Original Message-----
From: Mike Walter [mailto:[EMAIL PROTECTED] Sent: Friday, February 24, 2006 2:58 PM
To: [email protected]
Subject: Re: vmfinfo ---


Chris, Are you executing VMFINFO from MAINT? From the missing file identifier, it appears that you are running z/VM 4.4.0 - it that actually true (when something isn't going right, always include basic questions)? That APAR VM63405 resulted in z/VM 440 PTF: UM31122, which was included on RSU 0403. What RSU level are you running. Alternatively, you could look in the CPLOAD MAP for VM36405 , it hit: MODULES/MACROS: CHPID HCPCCS HCPCSCBK HCPHCD HCPIOX HCPMES HCPMESA HCPMESB HCPMESE HCPOCO HCPOM1 HCPPOCO HCPQPS HCPRP HCPSYSCM HCPYCAD HCPYCPD HCPZSI Nut you really should determine why VMFINFO is not getting the results you expect.
Mike Walter
Hewitt Associates
The opinions expressed herein are mine alone, not my employer's.


"Little, Chris" <[EMAIL PROTECTED]> Sent by: "VM/ESA and z/VM Discussions" <[email protected]>
02/24/2006 02:47 PM
Please respond to
"VM/ESA and z/VM Discussions" <[email protected]>


To
[email protected] cc
Subject
Re: vmfinfo ---

        




great . . . . :

                           VMFINFO Main Panel



Select one of the following.  Then press enter.

PPF fileid ...... ZVM       PPF  D

Component name .. CP                 Setup ... YES

Product ID .....: 4VMVMB40           System .. VM



   Options: S - select

Option   Query

         Product description

         Product status

         Product requisites

         Product dependencies

         PTFs/APARs

         Serviceable parts/usable forms

         Miscellaneous









VMFINF2239I Setup did not complete successfully. Query results may be
invalid


Command ===>


-----Original Message-----
From: Jim Vincent [mailto:[EMAIL PROTECTED] Sent: Friday, February 24, 2006 2:38 PM
To: [email protected]
Subject: Re: vmfinfo ---

The default for VMFINFO is to NOT set up the disk accesses for the
component. Try this: VMFINFO ZVM CP (SETUP and then try your lookup again. If that too fails, then you have a key VMSES file M.I.A. - I presume you have backups? ;-)

_______________________________________
James Vincent
Systems Engineering Consultant
Nationwide Services Co., Technology Infrastructure Engineering Mainframe, z/VM and z/Linux Support One Nationwide Plaza 3-25-02
Columbus OH 43215-2220   U.S.A
Voice: (614) 249-5547    Fax: (614) 677-7681
mailto:[EMAIL PROTECTED]


VM/ESA and z/VM Discussions <[email protected]> wrote on 02/24/2006
03:33:52 PM:

[email protected]

For the most part I'm a linux, not VM geek, so I'm still
trying to
find
my
way around. I want to see the status of an APAR so I'm
using VMFINFO,
but I
get the error : VMFINF2233I Table 4VMVMB40 SRVREQT not
found. Query
cancelled

Any ideas?


                             PTF/APAR Queries

Enter a PTF or APAR number and type an option code. Then
press Enter.
 PPF fileid ...... ZVM       PPF  D
 Component name .. CP                 Setup ... NO
 Product ID .....: 4VMVMB40           System .. VM
 PTF number ......
 APAR number ..... VM63405

    Options: S - select
 Option   Query
          Status of PTF
          Requisites/supersedes of PTF
          Dependencies/superseding of PTF
          User memo of PTF
          Serviceable parts included by PTF

          Abstract of APAR(s)


VMFINF2233I Table 4VMVMB40 SRVREQT not found. Query cancelled

+--------------------------------------------------+
| Chris Little         OKDHS Platform Services   |
| IS Operating Systems Specialist IV             |
| email  [EMAIL PROTECTED]                  |
+--------------------------------------------------+



The information contained in this e-mail and any accompanying documents may contain information that is confidential or otherwise protected from disclosure. If you are not the intended recipient of this message, or if this message has been addressed to you in error, please immediately alert the sender by reply e-mail and then delete this message, including any attachments. Any dissemination, distribution or other use of the contents of this message by anyone other than the intended recipient is strictly prohibited.