Happened to us as well.  No SS7 meant no ISUP with other telcos and no LNP lookups.  Both primary and secondary were down.

There is a lot of A and B geo-redundancy in their SIGTRAN design.  Frustrating for it all to go down at the same time.

They have not shared the cause with us.  I have told them to send us an RFO.  Master ticket 681772.

outage start: 2024-09-11T10:13-0500
outage end: 2024-09-11T12:58-0500
outage duration: 2 hours 45 minutes

Mike Johnston
Wikstrom Telephone Company <https://wiktel.com/>

On 2024-09-11 11:22, Collin Rose via VoiceOps wrote:

We lost both our primary and backup SIGTRAN link to Inteliquent at 11:13 EST. Calling in they say some sort large scale outage. Anyone aware of any details ?

*Collin Rose*

DayStarrCommunications

E: [email protected] <mailto:[email protected]>

P: 989-720-6000

F: 989-720-6060
_______________________________________________
VoiceOps mailing list
[email protected]
https://puck.nether.net/mailman/listinfo/voiceops