In the Lagano experiment, the resistance of the heater decreased to one
third of its initial startup value. Riddle that one batman.

On Sat, Mar 21, 2015 at 1:33 AM, Alberto De Souza <
[email protected]> wrote:

> Hi Bob,
>
> On Fri, Mar 20, 2015 at 9:21 PM, Bob Cook <[email protected]> wrote:
>
>>  Alberto--
>>
>> You are correct that voltage and current gives integrated  power in the
>> section of the coil between the voltage  drop measurements.  However, if
>> your are interested in local power generation in the active region where
>> the fuel is, you need to know the resistance in that region and hence its
>> temperature together with the current to determine power applied to the
>> fuel.
>>
>
> Actually, the resistence of heating wires varies very little with
> temperature. In the case of Kanthal A-1 (that MFMP was using), it increases
> by a factor of only 5% from 100 to 1400 degress Celsius (see
> http://kanthal.com/en/products/material-datasheets/wire/resistance-heating-wire-and-resistance-wire/kanthal-a-1/).
> So, considering a high COP (3), this control-variable variance (the wire
> resistance in the reactors) is negligible.
>
> Alberto.
>
>
>> Bob
>>
>>
>