Also I note that there is no neutron detection in the radiation measurements

On 9 September 2012 10:29, Robert Lynn <[email protected]>wrote:

> reading about the thermal camera:
>
>
> http://www.optris.com/thermal-imager-pi160?file=tl_files/pdf/Downloads/Infrared%20Cameras/PI_Brochure.pdf
>
> http://www.optris.com/thermal-imager-pi160?file=tl_files/pdf/Downloads/IR-Basics.pdf
>
> Has stated accuracy of +/- 2% which at typical 1000K of Rossi's
> demonstration would be +/- 20K.  So not too bad, and supports claims but
> nowhere near as good as a thermocouple.  Rossi has at least done 1 thing
> right - painting the surface black to improve accuracy, but there is
> apparently some choice in spectral emission range and also it is only rated
> for 900°C, so pretty good chance for errors in setup and trying to operate
> outside measurement range.
>

Reply via email to