Hi,
I am new with weewx: it is installed on a pi and my oregon lw30x is 
connected to my LAN, 
i am not able to get data from it, i have the following messages in Syslog 
when running "weewxd /etc/weewx/weewx.conf"

Dec  3 18:29:48 raspberrypi weewx[1362]: engine: Initializing engine
Dec  3 18:29:48 raspberrypi weewx[1362]: engine: Loading station type 
Interceptor (user.interceptor)
Dec  3 18:29:48 raspberrypi weewx[1362]: interceptor: MainThread: driver 
version is 0.41
Dec  3 18:29:48 raspberrypi weewx[1362]: interceptor: MainThread: device 
type: lw30x
Dec  3 18:29:48 raspberrypi weewx[1362]: interceptor: MainThread: sensor 
map: {'inTemp': 'ot.2:*.*', 'outTemp': 'ot.1:*.*'}
Dec  3 18:29:48 raspberrypi weewx[1362]: interceptor: MainThread: mode is 
listen
Dec  3 18:29:48 raspberrypi weewx[1362]: interceptor: MainThread: listen on 
192.168.1.19:8080
Dec  3 18:29:48 raspberrypi weewx[1362]: import of driver failed: [Errno 
99] Cannot assign requested address (<class 'socket.error'>)
Dec  3 18:29:48 raspberrypi weewx[1362]: engine: Unable to load driver: 
[Errno 99] Cannot assign requested address
Dec  3 18:29:48 raspberrypi weewx[1362]:     ****  Exiting…


in fact i am not sure about which port listen to the weather station, any 
idea ???
currently, the weewx.conf contents:
station_type = Interceptor
….
    driver = user.interceptor
    # Specify the hardware device to capture.  Options include:
    #   acurite-bridge - acurite internet bridge
    #   observer - fine offset WH2600/HP1000/HP1003, aka 'observer'
    #   lw30x - oregon scientific LW301/LW302
    #   lacrosse-bridge - lacrosse GW1000U/C84612 internet bridge
    device_type = lw30x
    address = 192.168.1.19
    port=8080
    [[sensor_map]]
        inTemp = ot.2:*.*    # sensor on channel 2
        outTemp = ot.1:*.*    # sensor on channel 1

Reply via email to