Luc and Paul Almost everything for me is decoding properly:
Outside Temperature 46.8°F (Validated against console) Humidity 59% (Validated against console) Wind N/A N/A ( N/A) (need to check my sensor map) Rain Rate 0.00 in/hr (check when raining) Rain Today 0.00 in (check when raining) Radiation 0 W/m² (Valid) Thanks Rich On Thursday, March 28, 2019 at 9:42:30 PM UTC-4, rich T wrote: > > Paul > > My Humidity value is being reported correctly. I did not update the > rtldavis file. > > LOOP: 2019-03-28 21:35:14 EDT (1553823314) dateTime: 1553823314, > maxSolarRad: 0.0, outHumidity: 59.7, rainRate: 0, usUnits: 1. The issue > I'm having is wind and wind direction is not being decoded. > > Rich > > > On Thursday, March 28, 2019 at 8:14:29 PM UTC-4, Paul Anderson wrote: >> >> Luc and Rich >> >> Had been doing the testing on a laptop which didn't have Weewx installed >> on. Today I installed everything on my PI3 development machine. I can't >> seem to get humidity to report correctly.This message shows in weex log: >> >> Mar 28 19:49:54 pi3-dev weewx[1837]: engine: 2019-03-28 19:49:54 EDT >> (1553816994) LOOP value 'outHumidity' 216.9 outside limits (0.0, 100.0) >> >> If I change line 1182 of rtldavis.py from: humidity = humidity_raw / >> 10.0 to humidity = humidity_raw / 10.0 no errors but wrong humidity >> value. Current real humidity here is 50% to 60% >> Where to start? :) >> >> Thanks, >> Paul >> >> On Thursday, March 28, 2019 at 7:40:22 AM UTC-4, rich T wrote: >>> >>> Luc >>> >>> Thanks...I figured it was a configuration error on my part. Later this >>> evening will give it a try. >>> >>> Thanks >>> Rich >>> >>> On Thursday, March 28, 2019 at 7:30:52 AM UTC-4, [email protected] >>> wrote: >>> >>>> On Wednesday, 27 March 2019 18:27:40 UTC-3, rich T wrote: >>>>> >>>>> Looks like I'm only decoding a couple of the data fields, in which >>>>> could be configuration error on my part. The driver did crash due to a >>>>> "none type" error, again the cause could be configuration error on my >>>>> part. >>>>> >>>> >>>> Rich, >>>> >>>> Your command line contained the phrase "[options]". This is not >>>> recognized by the go-parser and all entries which come after are >>>> neglected. >>>> Therefore no messages were received because you've got the default >>>> EU-frequencies. >>>> The init value of pct_good was none, I better change it to 0.0 to avoid >>>> the type error. This error only happens when no single message is received >>>> during 5 minutes. >>>> >>>> I will change the programs main.go and weewx-rtldavis as follows: >>>> - The -tf and -tr option are required (program weewx-rtldavis will add >>>> them automatically) >>>> - When -tf and/or -tr is missing, main.go report: EXIT PROGRAM with a >>>> description. >>>> - weewx-rtldavis will end itself (and rtldavis.go) when it sees this >>>> message. (when rtldavis should stop itself, it won't help because >>>> weewx-rtldavis will restart the program again after 60 seconds). >>>> >>>> Luc >>>> >>>