Luc and Paul

Almost everything for me is decoding properly:

Outside Temperature 46.8°F (Validated against console)
Humidity 59%  (Validated against console)
Wind N/A N/A ( N/A)  (need to check my sensor map)
Rain Rate 0.00 in/hr (check when raining)
Rain Today 0.00 in (check when raining)
Radiation 0 W/m²  (Valid)

Thanks
Rich

On Thursday, March 28, 2019 at 9:42:30 PM UTC-4, rich T wrote:
>
> Paul
>
> My Humidity value is being reported correctly.  I did not update the 
> rtldavis file.
>
> LOOP:   2019-03-28 21:35:14 EDT (1553823314) dateTime: 1553823314, 
> maxSolarRad: 0.0, outHumidity: 59.7, rainRate: 0, usUnits: 1.  The issue 
> I'm having is wind and wind direction is not being decoded.
>
> Rich
>
>
> On Thursday, March 28, 2019 at 8:14:29 PM UTC-4, Paul Anderson wrote:
>>
>> Luc and Rich
>>
>> Had been doing the testing on a laptop which didn't have Weewx installed 
>> on. Today I installed everything on my PI3 development machine. I can't 
>> seem to get humidity to report correctly.This message shows in weex log:
>>
>> Mar 28 19:49:54 pi3-dev weewx[1837]: engine: 2019-03-28 19:49:54 EDT 
>> (1553816994) LOOP value 'outHumidity' 216.9 outside limits (0.0, 100.0)
>>
>> If I change line 1182 of  rtldavis.py  from: humidity = humidity_raw / 
>> 10.0    to humidity = humidity_raw / 10.0 no errors but wrong humidity 
>> value. Current real humidity here is 50% to 60%
>> Where to start? :)
>>
>> Thanks,
>> Paul
>>
>> On Thursday, March 28, 2019 at 7:40:22 AM UTC-4, rich T wrote:
>>>
>>> Luc
>>>
>>> Thanks...I figured it was a configuration error on my part. Later this 
>>> evening will give it a try.
>>>
>>> Thanks
>>> Rich
>>>
>>> On Thursday, March 28, 2019 at 7:30:52 AM UTC-4, [email protected] 
>>> wrote:
>>>
>>>> On Wednesday, 27 March 2019 18:27:40 UTC-3, rich T wrote:
>>>>>
>>>>> Looks like I'm only decoding a couple of the data fields, in which 
>>>>> could be configuration error on my part.  The driver did crash due to a 
>>>>> "none type" error, again the cause could be configuration error on my 
>>>>> part.
>>>>>
>>>>
>>>> Rich,
>>>>
>>>> Your command line contained the phrase "[options]". This is not 
>>>> recognized by the go-parser and all entries which come after are 
>>>> neglected. 
>>>> Therefore no messages were received because you've got the default 
>>>> EU-frequencies.
>>>> The init value of pct_good was none, I better change it to 0.0 to avoid 
>>>> the type error. This error only happens when no single message is received 
>>>> during 5 minutes.
>>>>
>>>> I will change the programs main.go and weewx-rtldavis as follows:
>>>> - The -tf and -tr option are required (program weewx-rtldavis will add 
>>>> them automatically)
>>>> - When -tf and/or -tr is missing, main.go report: EXIT PROGRAM with a 
>>>> description.
>>>> - weewx-rtldavis will end itself (and rtldavis.go) when it sees this 
>>>> message. (when rtldavis should stop itself, it won't help because 
>>>> weewx-rtldavis will restart the program again after 60 seconds).
>>>>
>>>> Luc
>>>>
>>>

Reply via email to