Yes they are in kph.  Here is my Std archive section from weewx.conf

[StdArchive]

    # If the station hardware supports data logging then the archive 
interval
    # will be downloaded from the station. Otherwise, specify it (in 
seconds).
    archive_interval = 300

    # How long to wait (in seconds) before processing new archive data. Must
    # be greater than zero.
    archive_delay = 15

    # If possible, new archive records are downloaded from the station
    # hardware. If the hardware does not support this, then new archive
    # records will be generated in software.
    # Set the following to "software" to force software record generation.
    record_generation = hardware

    # Whether to include LOOP data in hi/low statistics
    loop_hilo = True

    # The data binding used to save archive records
    data_binding = wx_binding


On Wednesday, August 17, 2016 at 9:06:08 PM UTC-4, gjr80 wrote:
>
> Good progress, I still need to have a closer look at the template, I think 
> a couple of other changes are required. Did you notice that your graph is 
> in kph and the values shown in mph?
>
> Gary
>

-- 