On Thursday, December 8, 2016 at 4:32:11 PM UTC-5, Matt VanGiesen wrote:
>
> 2032 in mode 4
>
> But, when verifying the weewx.conf, I found typo in the model number...I 
> believe when I re-installed after the upgrade weewx used an archived .conf 
> file that was incorrect. I'm vetting it now for more errors..
>>
>>
>>
matt,

first be sure that the console is in mode 4 (when you power cycle it, it 
will default to mode 2, which means no usb communication)

if you see log messages about failed attempt x to get LOOP data more than 3 
or 4 times, then unplug the usb cable from the computer or console, wait 30 
seconds, then plug it back in.  no need to restart the computer, restart 
weewx, or power cycle the acurite console.  unplug/replug will force a usb 
reset. (for some reason a software reset of the usb does not always work on 
the acurite consoles)

let us know how it goes

m

-- 
You received this message because you are subscribed to the Google Groups 
"weewx-user" group.
To unsubscribe from this group and stop receiving emails from it, send an email 
to [email protected].
For more options, visit https://groups.google.com/d/optout.

Reply via email to