Sorry, I did not see this message before replying to your other message. The sensor mappings were changed in v3.6.1 (released 10/13/2016). See issue #164 <https://github.com/weewx/weewx/issues/164>.
-tk On Fri, Dec 16, 2016 at 4:24 PM, <[email protected]> wrote: > I just upgraded my weewx installation to version 3.6.2 from an earlier > version. I have two extra temperature/humidity sensors attached to my > system as devices 2 and 3 on the console. They were reporting properly > under the earlier version of weewx but now they are out of sequence. It > seems device three is now recorded as device two and device two isn't > captured. > > I believe there was an update to the WMR200 driver that caused this (from > various postings I've found) but I can't find any information on how to fix > the problem. I'm not really happy with the idea that I should reconfigure > my sensors, but I suspect that might work. Any help would be appreciated. > > -- > You received this message because you are subscribed to the Google Groups > "weewx-user" group. > To unsubscribe from this group and stop receiving emails from it, send an > email to [email protected]. > For more options, visit https://groups.google.com/d/optout. > -- You received this message because you are subscribed to the Google Groups "weewx-user" group. To unsubscribe from this group and stop receiving emails from it, send an email to [email protected]. For more options, visit https://groups.google.com/d/optout.