This is the only reference to the change but isn't very explicit: *Remapped sensor identifiers in wmr200 driver so that extraTemp1 and extraHumid1 are usable.*
It didn't explain the change very well and I wasn't able to determine it would break parts of my setup. On Friday, December 16, 2016 at 11:23:06 PM UTC-8, Andrew Milner wrote: > > Did you read the release notes before you updated?? > http://weewx.com/docs/changes.txt > > see the notes regarding 3.6.1 > > > > On Saturday, 17 December 2016 09:01:19 UTC+2, [email protected] wrote: > >> Yes, what you have stated is my goal. However, I made the additions to >> the weewx.conf file and restarted weewx, but it doesn't seem to have taken >> effect. I'll reboot the system tomorrow and tinker with it some more. >> >> Thanks for your response. It has been very helpful. I wish I had found >> out about the change before I updated. >> >> On Friday, December 16, 2016 at 5:09:24 PM UTC-8, Tom Keffer wrote: >>> >>> I'll try and be as explicit as possible. >>> >>> For the WMR200 sensor #2, your old driver emitted extraTemp2, and, I >>> presume, it was recorded in your database as extraTemp2. >>> >>> The new driver will emit extraTemp1. If you do nothing, it will be >>> recorded in the database as extraTemp1. >>> >>> My suggestion copies the data from extraTemp1 to extraTemp2, then sets >>> extraTemp1 to null. This way, the data will be recorded in the database as >>> extraTemp2, just as before. I assume this is what you want. >>> >>> -tk >>> >>> On Fri, Dec 16, 2016 at 4:59 PM, <[email protected]> wrote: >>> >>>> Trying to clarify this in my own mind... >>>> >>>> In the corrections you listed which items represent the data as >>>> understood by the WMR200? I wan't extraTemp3 from the WMR200 to be >>>> extraTemp3 for weewx. With the updated driver, as I understand it, >>>> extraTemp3 is now read from the station as extraTemp2 (sensor number minus >>>> 1), yes? Is that what these "corrections" do? >>>> >>>> >>>> On Friday, December 16, 2016 at 4:44:00 PM UTC-8, [email protected] >>>> wrote: >>>>> >>>>> Has this been implemented? From the issue posting it seemed that this >>>>> wasn't available yet. >>>>> >>>>> On Friday, December 16, 2016 at 4:37:17 PM UTC-8, Tom Keffer wrote: >>>>>> >>>>>> I realized my response does not help you very much. >>>>>> >>>>>> One thing you could do is remap them using the StdCalibrate facility: >>>>>> >>>>>> [StdCalibrate] >>>>>> [[Corrections]] >>>>>> extraTemp3 = extraTemp2 >>>>>> extraTemp2 = extraTemp1 >>>>>> extraTemp1 = None >>>>>> >>>>>> This would cause the value in extraTemp2 to appear as extraTemp3, the >>>>>> value in extraTemp1 to appear as extraTemp2. I believe this is what you >>>>>> had >>>>>> before. >>>>>> >>>>>> I also know that Matthew is working on a more general mapping >>>>>> facility, but it probably won't be available for a while. >>>>>> >>>>>> -tk >>>>>> >>>>>> On Fri, Dec 16, 2016 at 4:33 PM, Thomas Keffer <[email protected]> >>>>>> wrote: >>>>>> >>>>>>> Sorry, I did not see this message before replying to your other >>>>>>> message. >>>>>>> >>>>>>> The sensor mappings were changed in v3.6.1 (released 10/13/2016). >>>>>>> See issue #164 <https://github.com/weewx/weewx/issues/164>. >>>>>>> >>>>>>> -tk >>>>>>> >>>>>>> On Fri, Dec 16, 2016 at 4:24 PM, <[email protected]> wrote: >>>>>>> >>>>>>>> I just upgraded my weewx installation to version 3.6.2 from an >>>>>>>> earlier version. I have two extra temperature/humidity sensors >>>>>>>> attached to >>>>>>>> my system as devices 2 and 3 on the console. They were reporting >>>>>>>> properly >>>>>>>> under the earlier version of weewx but now they are out of sequence. >>>>>>>> It >>>>>>>> seems device three is now recorded as device two and device two isn't >>>>>>>> captured. >>>>>>>> >>>>>>>> I believe there was an update to the WMR200 driver that caused this >>>>>>>> (from various postings I've found) but I can't find any information on >>>>>>>> how >>>>>>>> to fix the problem. I'm not really happy with the idea that I should >>>>>>>> reconfigure my sensors, but I suspect that might work. Any help would >>>>>>>> be >>>>>>>> appreciated. >>>>>>>> >>>>>>>> -- >>>>>>>> You received this message because you are subscribed to the Google >>>>>>>> Groups "weewx-user" group. >>>>>>>> To unsubscribe from this group and stop receiving emails from it, >>>>>>>> send an email to [email protected]. >>>>>>>> For more options, visit https://groups.google.com/d/optout. >>>>>>>> >>>>>>> >>>>>>> >>>>>> -- >>>> You received this message because you are subscribed to the Google >>>> Groups "weewx-user" group. >>>> To unsubscribe from this group and stop receiving emails from it, send >>>> an email to [email protected]. >>>> For more options, visit https://groups.google.com/d/optout. >>>> >>> >>> -- You received this message because you are subscribed to the Google Groups "weewx-user" group. To unsubscribe from this group and stop receiving emails from it, send an email to [email protected]. For more options, visit https://groups.google.com/d/optout.