Are we talking about in the weewx.conf file?  (Yes)
Or in the acurite.py driver?  

What is the location of the driver file?

Dennis

On Friday, December 30, 2016 at 8:44:16 AM UTC-8, Andrew Milner wrote:
>
> So did you set ignore_bounds to true and still get the same result?
>
>
>
> On Friday, 30 December 2016 18:13:21 UTC+2, Andrew Milner wrote:
>
>> See If this thread helps
>>
>> https://groups.google.com/forum/?fromgroups#!msg/weewx-user/0WabUwmGPAU/ZjaA8xnVKQAJ;context-place=searchin/weewx-user/accurite$20calibration$20constants%7Csort:relevance
>>
>>
>>
>>
>> On Friday, 30 December 2016 16:57:43 UTC+2, Dennis Hall wrote:
>>
>>> I recently installed weewx on my Raspberry Pi.  I am missing the 
>>> Barometer readings
>>>
>>> http://kk7x.duckdns.org/weewx
>>>
>>> Acurite 1035 USB 4  Installed with Debian
>>>
>>> Anyway to fix this issue?
>>>
>>> Dennis
>>>
>>> Dec 30 06:43:26 raspberrypi weewx[723]: acurite: Found station at 
>>> bus=001 device=004
>>> Dec 30 06:43:26 raspberrypi weewx[723]: acurite: R2: unknown calibration 
>>> constants: 02 00 00 43 ea 0c d7 01 66 06 86 8a 1c 15 ab 09 c4 05 fd 06 0a 
>>> 87 e9 9e 70
>>>
>>> ​[AcuRite]
>>>     # This section is for AcuRite weather stations.
>>>     
>>>     # The station model, e.g., 'AcuRite 01025' or 'AcuRite 02032C'
>>>     model = AcuRite 01035
>>>     
>>>     # The driver to use:
>>>     driver = weewx.drivers.acurite
>>>     use_constants = True
>>>
>>> [StdQC]
>>>     
>>>     [[MinMax]]
>>>         barometer = 28, 34.5, inHg
>>>         outTemp = -40, 120, degree_F
>>>         inTemp = 10, 120, degree_F
>>>         outHumidity = 0, 100
>>>         inHumidity = 0, 100
>>>         windSpeed = 0, 120, mile_per_hour
>>>         pressure = 24, 34.5, inHg
>>>
>>> StdWXCalculate]
>>>     
>>>     [[Calculations]]
>>>         # Derived quantities are calculated by this service. Possible 
>>> values are:
>>>         #  hardware        - use the value provided by hardware
>>>         #  software        - use the value calculated by weewx
>>>         #  prefer_hardware - use value provide by hardware if available,
>>>         #                      otherwise use value calculated by weewx
>>>         
>>>         pressure = prefer_hardware
>>>         barometer = prefer_hardware
>>>         altimeter = prefer_hardware
>>>         windchill = prefer_hardware
>>>         heatindex = prefer_hardware
>>>         dewpoint = prefer_hardware
>>>         inDewpoint = prefer_hardware
>>>         rainRate = prefer_hardware
>>>
>>>
>>>

-- 
You received this message because you are subscribed to the Google Groups 
"weewx-user" group.
To unsubscribe from this group and stop receiving emails from it, send an email 
to [email protected].
For more options, visit https://groups.google.com/d/optout.

Reply via email to