I would have to probably also use the post interval code in my ftp settings for my website also so it does not post every 1 minute to my website to correct.
So if I understand you correctly the archive setting of 300 is for how fast it takes the readings into the database only. On Jul 3, 2017 07:06, "Andrew Milner" <[email protected]> wrote: > As you are trying to post to WU and WB at 60 second intervals I think you > will find that you will need your archive interval to be set to 60 seconds, > and then use the post_interval settings to delay the postings to other > sites such as CWOP - rather than trying to output on LOOP records (which as > far as I am aware is only implemented for WU rapidfire, and which you have > already said won't woprk for Accurite stations anyway since they output > partial packets. > > > > On 3 July 2017 at 14:57, John Jensen <[email protected]> wrote: > >> I am trying to achieve 1) posting to a services default and 2) get >> weather underground and weatherbug to as close to real time as possible. >> >> I do know the rapid fire does not work with Acurite stations. It gives a >> -- in the barometer and a nAn in the temp. >> >> So I was thinking by using the code Tom posted earlier that it would tell >> that service to post at that set interval. >> >> So I had set WU and WB to 60 second post to try and achieve as close to >> real time and then set PWS to 300 seconds and WeatherCloud and CWOP to 600 >> seconds. >> >> Tom had said it was untested so I tried it. >> >> On Jul 3, 2017 06:38, "Andrew Milner" <[email protected]> >> wrote: >> >> I think there may be a terminological issue here. What exactly are you >> trying to achieve? >> >> Weewx will create archive records in the weewx database according to the >> archive interval specified - I your case every 300 seconds >> >> Reports are run every archive interval, but specific reports may be >> delayed using the cron-like facility. Except for WU rapidfire (which is >> bound to LOOP records) the restful services are run every archive record. >> >> I THINK that the post_interval is similar in that the restx services are >> attempted to be run once per archive interval, but may be deferred until at >> least post_interval has passed for specific services. ie the post_interval >> may defer a restx update until post_interval or the next running, but >> cannot be used to increase the frequency to less than archive interval. >> >> I may be talking total gibberish though!! >> >> >> >> On Monday, 3 July 2017 13:48:24 UTC+3, JJ Drones1 wrote: >> >>> Well it has been running over night and will run like this till I get >>> home from work. >>> >>> But it only updates at archive rate default of 300 seconds and does do >>> the posting intervals. >>> >>> So I am unable to do real time 60 second updates on weather underground >>> or rapid fire, with rapid fire set to true acrite stations get nA or -- in >>> the updates. >>> >>> I set rapid fire before I put the code of the post interval in to test >>> it again. Then returned it to false then inserted the post interval code to >>> test. >>> >>> Oh well guess I have to live with the 5min 300sec archival update. >>> >>> -- >> You received this message because you are subscribed to a topic in the >> Google Groups "weewx-user" group. >> To unsubscribe from this topic, visit https://groups.google.com/d/to >> pic/weewx-user/qhdN8xgyPxE/unsubscribe. >> To unsubscribe from this group and all its topics, send an email to >> [email protected]. >> For more options, visit https://groups.google.com/d/optout. >> >> >> -- >> You received this message because you are subscribed to a topic in the >> Google Groups "weewx-user" group. >> To unsubscribe from this topic, visit https://groups.google.com/d/to >> pic/weewx-user/qhdN8xgyPxE/unsubscribe. >> To unsubscribe from this group and all its topics, send an email to >> [email protected]. >> For more options, visit https://groups.google.com/d/optout. >> > > -- > You received this message because you are subscribed to a topic in the > Google Groups "weewx-user" group. > To unsubscribe from this topic, visit https://groups.google.com/d/ > topic/weewx-user/qhdN8xgyPxE/unsubscribe. > To unsubscribe from this group and all its topics, send an email to > [email protected]. > For more options, visit https://groups.google.com/d/optout. > -- You received this message because you are subscribed to the Google Groups "weewx-user" group. To unsubscribe from this group and stop receiving emails from it, send an email to [email protected]. For more options, visit https://groups.google.com/d/optout.