or here http://www.davisnet.com/product_documents/weather/manuals/07395-210_GSG_06510_6555.pdf
On Tuesday, 28 November 2017 13:35:54 UTC+2, Andrew Milner wrote: > Re vantage vue baud rate setting - from the manual: > > How to Display the Baud Rate To display the Baud Rate settings on a > Vantage Pro or Vantage Pro2 console, make sure the data logger is installed > and then continue using the following procedures: • Enter the console Setup > Mode by pressing and holding DONE, then pressing the (-) key. • Use the BAR > and DONE to scroll to the Baud Rate settings screen: > Use the up (+) and down (-) arrows to change the Baud Rate setting, if > needed. Press and hold DONE to return the console to the current weather > mode. • Use the fastest Baud Rate your computer can handle. 19200 is the > fastest Baud Rate available and is the default setting on the console. • > Press DONE when you have the correct Baud Rate on the console screen. > > > To display the Baud Rate settings on a Vantage Vue console, make sure the > data logger is installed and then continue using the following procedures: > • Enter the console Setup Mode by pressing and holding DONE, then pressing > the (-) key. > 8 > USB Hardware Installation > • Press BAR to get to the Baud Rate settings screen: > Use the up (+) and down (-) arrows to change the Baud Rate setting, if > needed. Press and hold DONE to return the console to the current weather > mode. • Use the fastest Baud Rate your computer can handle. 19200 is the > fastest Baud Rate available and is the default setting on the console. • > Press and hold DONE when you have the correct Baud Rate on the console > screen > Note: The data logger does not require a constant connection with a > computer to continue logging and storing data. Although the data logger > should remain connected to the console at all times, the data logger needs > to be connected to the computer only when data is being downloaded or when > the computer is actively using data from the data logger. The data logger > and console can be disconnected from the computer if they are placed in a > location where the data logger cable cannot reach. However, WeatherLink’s > bulletin, summary, or other real-time window displays are accessible only > if the data logger and console are connected to the computer. > > > On Tuesday, 28 November 2017 12:46:57 UTC+2, Antony K. wrote: > >> Nov 28 09:25:34 raspberrypi wee_device[12649]: vantage: Archive memory >> cleared >> Nov 28 09:25:55 raspberrypi weewx[12744]: engine: Initializing weewx version >> 3.4.0 >> Nov 28 09:25:55 raspberrypi weewx[12744]: engine: Using Python 2.7.3 >> (default, Mar 18 2014, 05:13:23) #012[GCC 4.6.3] >> Nov 28 09:25:55 raspberrypi weewx[12744]: engine: Platform >> Linux-4.4.16-v7+-armv7l-with-debian-7.8 >> Nov 28 09:25:55 raspberrypi weewx[12744]: engine: pid file is >> /var/run/weewx.pid >> Nov 28 09:25:55 raspberrypi weewx[12750]: engine: Using configuration file >> /home/weewx/weewx.conf >> Nov 28 09:25:55 raspberrypi weewx[12750]: engine: Loading station type >> Vantage (weewx.drivers.vantage) >> Nov 28 09:25:55 raspberrypi weewx[12750]: engine: StdConvert target unit is >> 0x1 >> Nov 28 09:25:55 raspberrypi weewx[12750]: engine: Archive will use data >> binding wx_binding >> Nov 28 09:25:55 raspberrypi weewx[12750]: engine: Record generation will be >> attempted in 'hardware' >> Nov 28 09:25:55 raspberrypi weewx[12750]: engine: Using archive interval of >> 300 seconds >> Nov 28 09:25:56 raspberrypi weewx[12750]: manager: Created and initialized >> table 'archive' in database 'weewx.sdb' >> Nov 28 09:25:56 raspberrypi weewx[12750]: manager: Created daily summary >> tables >> Nov 28 09:25:56 raspberrypi weewx[12750]: engine: Using binding 'wx_binding' >> to database 'weewx.sdb' >> Nov 28 09:25:56 raspberrypi weewx[12750]: engine: Starting backfill of daily >> summaries >> Nov 28 09:25:56 raspberrypi weewx[12750]: engine: Daily summaries up to date. >> Nov 28 09:25:56 raspberrypi weewx[12750]: engine: Starting up weewx version >> 3.4.0 >> Nov 28 09:25:56 raspberrypi weewx[12750]: engine: Clock error is -154.87 >> seconds (positive is fast) >> Nov 28 09:25:57 raspberrypi weewx[12750]: vantage: Clock set to 2017-11-28 >> 09:25:58 EET (1511853958) >> Nov 28 09:25:58 raspberrypi weewx[12750]: engine: Starting main packet loop. >> Nov 28 09:30:17 raspberrypi weewx[12750]: manager: added record 2017-11-28 >> 09:30:00 EET (1511854200) to database 'weewx.sdb' >> Nov 28 09:30:17 raspberrypi weewx[12750]: manager: added record 2017-11-28 >> 09:30:00 EET (1511854200) to daily summary in 'weewx.sdb' >> Nov 28 09:30:27 raspberrypi weewx[12750]: cheetahgenerator: Generated 17 >> files for report StandardReport in 10.02 seconds >> Nov 28 09:30:39 raspberrypi weewx[12750]: genimages: Generated 49 images for >> StandardReport in 11.14 seconds >> Nov 28 09:30:39 raspberrypi weewx[12750]: reportengine: copied 14 files to >> /home/weewx/public_html >> Nov 28 09:30:44 raspberrypi weewx[12750]: reportengine: ftp'd 1 files in >> 5.56 seconds >> >> I have a USB logger. >> >> You won't believe what happening. >> >> After many trials and a long sleepless night while trying to solve the above >> problem, I concluded this: >> >> *In the Vantage Vue console settings the Serial Baud Rate option does not >> appear anywhere!* >> >> This is very strange. Also the Weewx program can not draw the data and the >> errors can be seen in syslog file. >> >> I went back to firmware version 3.00 and all problems were solved. >> >> What can be happening with the firmware version 4.18? >> >> -- You received this message because you are subscribed to the Google Groups "weewx-user" group. To unsubscribe from this group and stop receiving emails from it, send an email to [email protected]. For more options, visit https://groups.google.com/d/optout.