Hi,

Probably corrupted station memory from the power cut but impossible to say 
without seeing the logs. Software record generation works as it only uses the 
loop data from your console which is unaffected by corrupt station memory. On 
the other hand, hardware generation relies on archive records from your station 
and they are affected by corrupt station memory.

I would go back to hardware record generation, stop weeWX and clear the station 
memory using wee_device as per the 'Corrupt station memory' section in the 
User's Guide 
(http://weewx.com/docs/usersguide.htm#html_generated_but_not_updated). Note 
weeWX needs to be stopped before running wee_device. Start weeWX and monitor 
your logs. If all is not working post a log extract from when you just started 
weeWX including at least a couple of report cycles (archive intervals) of 
output. Don't omit anything from the logs.

Gary

-- 
You received this message because you are subscribed to the Google Groups 
"weewx-user" group.
To unsubscribe from this group and stop receiving emails from it, send an email 
to [email protected].
For more options, visit https://groups.google.com/d/optout.

Reply via email to