I'm not well versed on getting other pressure readings into weewx. I'm sure there is a way but might be more work for just a temp situation.
I think the distance packets should always show up, it would just show the last storm distance in the packets. Although I have a standalone lightning tower, not an atlas, so maybe the behavior is different. This site <https://www.wxforum.net/index.php?topic=30139.0> has some information on that discussion. Assigning battery to outTempBatteryStatus should work but I haven't done this. From my understanding, acurite signal for battery is either 1 or 0. On Thursday, September 17, 2020 at 1:51:19 PM UTC-4 wxwatching wrote: > I have ordered a pressure sensor, but delivery looks like it will take a > month. Meanwhile, I thought I could just use my own console from my AcuRite > 5-n-1 (Model 1036), but haven't figured out how to just use the pressure > readings from it and combine with my Atlas readings. > > So, I assume the distance.XXXX.AcuriteLightningPacket packets will not > show in the SDR output until an actual storm is taking place? > > In reference to the battery, is that to mapped then as: > > outTempBatteryStatus = battery..0222.AcuriteAtlasPacket > > On Thursday, September 17, 2020 at 8:58:53 AM UTC-4 [email protected] > wrote: > >> The lightning data is handled a bit differently and from searching the >> user group I was able to get it working with the following sensor map: >> >> [[sensor_map]] >> ....... >> lightning_distance = distance.XXXX.AcuriteLightningPacket >> strikes_total = strikes_total.XXXX.AcuriteLightningPacket >> [[deltas]] >> rain = rain_total >> lightning_strike_count = strikes_total >> >> and then in the calibration section in the weewx.conf file I added the >> following: >> >> [StdCalibrate] >> >> [[Corrections]] >> # For each type, an arbitrary calibration expression can be given. >> # It should be in the units defined in the StdConvert section. >> # Example: >> foo = foo + 0.2 >> lightning_distance = lightning_distance if lightning_strike_count >> > 0 else None >> >> More info here >> <https://groups.google.com/g/weewx-user/c/VBHMkb04kEk/m/_XLIZbIBBgAJ> >> >> I haven't been able to determine how to capture signal strength from >> Acurite via SDR. The battery status as I understand it is either "1" which >> is good or "0" which is bad. >> >> Depending on your setup, there are a couple ways to get pressure. I am >> using a raspberry pi 3 and added a pressure sensor to it using these >> instructions >> <https://github.com/bdwilson/acurite/blob/master/Pressure.md>. >> > -- You received this message because you are subscribed to the Google Groups "weewx-user" group. To unsubscribe from this group and stop receiving emails from it, send an email to [email protected]. To view this discussion on the web visit https://groups.google.com/d/msgid/weewx-user/c6521fe7-adf1-44d4-9e4f-331c017d4cdbn%40googlegroups.com.