Hi All,
I have been trying to coax rain data out of the WS90 and into weewx.
I assume that the local API is deprecated on the HP2560 as I can't appear
to get any details out of it on port 45000.
I am currently using the interceptor driver in listen mode on port 8080.
And I am able to log all data in WeeWX except rain from the piezo sensor,
and battery voltages.
I have tried mapping sensors to fields as below, to no avail, is anyone
able to assist with the interceptor driver, or is there another driver
better suited to my hardware?
Hardware:
-----------------
HP2564 - HP2560 & WS90
HP2560_C:
Hardware revision V2.0
Firmware: Pro_V1.9.0
EasyWeatherProv5.11
WS90:
Firmware 1.3.3
weewx.conf extract:
--------------------------------
driver = user.interceptor
device_type = ecowitt-client
port = 8080
iface = ens18
[[sensor_map_extensions]]
rain = drain_piezo
rainRate = rrain_piezo
bat_wind = wh90batt
bat_rain = ws90cap_volt
Am I using the right field names? Example output from the ws90 is as
follows:
PASSKEY: <redacted>
stationtype: EasyWeatherPro_V5.1.1
runtime: 2
dateutc: 2023-06-11 01:53:27
tempinf: 77.0
humidityin: 40
baromrelin: 30.224
baromabsin: 29.946
tempf: 61.2
humidity: 60
winddir: 12
windspeedmph: 5.14
windgustmph: 6.93
maxdailygust: 10.74
solarradiation: 270.64
uv: 2
rrain_piezo: 0.000
erain_piezo: 0.000
hrain_piezo: 0.000
drain_piezo: 0.000
wrain_piezo: 0.000
mrain_piezo: 1.209
yrain_piezo: 1.209
ws90cap_volt: 5.2
ws90_ver: 133
gain10_piezo: 1.15
gain20_piezo: 1.05
gain30_piezo: 1.00
gain40_piezo: 1.00
gain50_piezo: 1.00
wh90batt: 3.10
freq: 433M
model: HP2564CA_Pro_V1.9.0
interval: 30
Cheers,
Jason
--
You received this message because you are subscribed to the Google Groups
"weewx-user" group.
To unsubscribe from this group and stop receiving emails from it, send an email
to [email protected].
To view this discussion on the web visit
https://groups.google.com/d/msgid/weewx-user/8828c0f2-f040-4558-bf6d-f2ff1dedb0ben%40googlegroups.com.