*Good morning,*









*My WeeWX.sdb database works perfectly. I removed all unnecessary fields 
with sudo wee_database --drop-columns=XXX,YYY,ZZZ which worked perfectly.I 
renamed the field "heatindex1", from the base to "wetbulbTemp" with the 
command: sudo wee_database --rename-column=heatindex1 
--to-name=wetbulbTemp. Flawless.The problem is when I try to insert CSV 
data into the database using the wee_import.py utility.All fields work on 
import except the one renamed to "wetbulbTemp"...If I remove the 
wetbulbTemp field from the import configuration file (*.conf), the import 
is done without any problem.With the field renamed "wetbulbTemp", I get the 
following message:*

Using WeeWX configuration file /etc/weewx/weewx.conf
Starting wee_import...
A CSV import from source file '/home/pi/Documents/Bresser7in1/data5.csv' 
has been requested.
The following options will be used:
      config=/etc/weewx/weewx.conf, 
import-config=/home/pi/Documents/Bresser7in1/csv-Bresser.conf
      source=/home/pi/Documents/Bresser7in1/data5.csv, from=None, to=None
      dry-run=True, calc_missing=True, ignore_invalid_data=True
      slice=250, interval=conf, date/time_string_format=%Y-%m-%d %H:%M:%S
      delimiter=',', rain=cumulative, wind_direction=[0.0, 360.0]
      UV=True, radiation=True
Using database binding 'wx_binding', which is bound to database 'weewx.sdb'
Destination table 'archive' unit system is '0x01' (US).
Missing derived observations will be calculated.
This is a dry run, imported data will not be saved to archive.
Starting dry run import ...
Obtaining raw import data for period 1 ...
The following imported field-to-WeeWX field map will be used:
      source field 'dateTime' in units 'unix_epoch' --> WeeWX field 
'dateTime'
      source field 'barometer' in units 'hPa' --> WeeWX field 'barometer'
      source field 'inTemp' in units 'degree_C' --> WeeWX field 'inTemp'
      source field 'outTemp' in units 'degree_C' --> WeeWX field 'outTemp'
      source field 'inHumidity' in units 'percent' --> WeeWX field 
'inHumidity'
      source field 'outHumidity' in units 'percent' --> WeeWX field 
'outHumidity'
      source field 'windSpeed' in units 'km_per_hour' --> WeeWX field 
'windSpeed'
      source field 'windDir' in units 'degree_compass' --> WeeWX field 
'windDir'
      source field 'windGust' in units 'km_per_hour' --> WeeWX field 
'windGust'
      source field 'rainRate' in units 'mm_per_hour' --> WeeWX field 
'rainRate'
      source field 'rain' in units 'mm' --> WeeWX field 'rain'
      source field 'dewpoint' in units 'degree_C' --> WeeWX field 'dewpoint'
      source field 'windchill' in units 'degree_C' --> WeeWX field 
'windchill'
      source field 'radiation' in units 'watt_per_meter_squared' --> WeeWX 
field 'radiation'
      source field 'UV' in units 'uv_index' --> WeeWX field 'UV'
      source field 'extraTemp1' in units 'degree_C' --> WeeWX field 
'extraTemp1'
      source field 'extraTemp2' in units 'degree_C' --> WeeWX field 
'extraTemp2'
      source field 'extraTemp3' in units 'degree_C' --> WeeWX field 
'extraTemp3'
      source field 'extraTemp4' in units 'degree_C' --> WeeWX field 
'extraTemp4'
      source field 'extraHumid1' in units 'percent' --> WeeWX field 
'extraHumid1'
      source field 'extraHumid2' in units 'percent' --> WeeWX field 
'extraHumid2'
      source field 'extraHumid3' in units 'percent' --> WeeWX field 
'extraHumid3'
      source field 'extraHumid4' in units 'percent' --> WeeWX field 
'extraHumid4'
      source field 'wetbulbTemp' in units 'degree_C' --> WeeWX field 
'wetbulbTemp'
Raw import data read successfully for period 1.
Mapping raw import data for period 1 ...
Traceback (most recent call last):
   File "/usr/share/weewx/wee_import", line 900, in <module>
     hand()
   File "/usr/share/weewx/wee_import", line 830, in main
     source_obj.run()
   File "/usr/share/weewx/weeimport/weeimport.py", line 421, in run
     _mapped_data = self.mapRawData(_raw_data, self.archive_unit_sys)
   File "/usr/share/weewx/weeimport/weeimport.py", line 981, in mapRawData
     weewx.units.obs_group_dict[_field])
   File "/usr/lib/python3.9/collections/__init__.py", line 941, in 
__getitem__
     return self.__missing__(key) # support subclasses that define 
__missing__
   File "/usr/lib/python3.9/collections/__init__.py", line 933, in 
__missing__
     raiseKeyError(key)
*KeyError: 'wetbulbTemp'*



*I couldn't find any help in the WeeWX documentation on this.What is 
happening with this renamed field and what is the solution to integrate the 
CSV data of this field into my modified weewx.sdb database?*

Thank you...

-- 
You received this message because you are subscribed to the Google Groups 
"weewx-user" group.
To unsubscribe from this group and stop receiving emails from it, send an email 
to [email protected].
To view this discussion on the web visit 
https://groups.google.com/d/msgid/weewx-user/6c188279-16f6-448d-a234-0f8d6e3e6437n%40googlegroups.com.