Thanks Gary for your response.
I added :

import weewx.units
weewx.units.obs_group_dict['wetbulbTemp'] = 'group_temperature'

in file /usr/share/weewx/weecfg/extension.py

It didn't change anything about the problem when using wee_import.py, I
still get the same error.
I specify that I did not create a field ['wetbulbTemp'] in the WeeWX
database but simply renamed ['heatindex1'] to ['wetbulbTemp'].

The WeeWX daemon does not enter (in my opinion) into the problem since to
use the wee_import.py utility it is strongly advised to stop it... What I
do.

I saw in the documentation what you are talking about where it is a
question of creating a user/electricity.py service, but unfortunately did
not quite understand where this electricity.py file went... :-(

*Rémy LAVABRE*


Le sam. 29 juil. 2023 à 10:04, gjr80 <[email protected]> a écrit :

> Your problem is that wee_database --add_column/--rename_column makes all
> necessary changes to the database, but it does not make any change to the
> WeeWX unit system; in other words WeeWX knows there is a field wetbulbTemp
> in the database but does not know if it is a temperature, wind speed or
> rainfall. To fix this you need to add wetbulbTemp to the WeeWX unit
> system, the usual approach for this is to add a couple of lines of code to
> user/extensions.py (refer to Assigning a unit group
> <http://weewx.com/docs.html/latest/customizing.htm#Assigning_a_unit_group>
> in the Customization Guide
> <http://weewx.com/docs.html/latest/customizing.htm>), in your case
> something like the following should work (untested):
>
> import weewx.units
> weewx.units.obs_group_dict['wetbulbTemp'] = 'group_temperature'
>
> For the WeeWX daemon this will take effect when WeeWX is restarted, but
> for the purposes of wee_import it should work straight away.
>
> Gary
> On Saturday, 29 July 2023 at 08:36:33 UTC+1 [email protected] wrote:
>
>> *Good morning,*
>>
>>
>>
>>
>>
>>
>>
>>
>>
>>
>> *My WeeWX.sdb database works perfectly. I removed all unnecessary fields
>> with sudo wee_database --drop-columns=XXX,YYY,ZZZ which worked perfectly.I
>> renamed the field "heatindex1", from the base to "wetbulbTemp" with the
>> command: sudo wee_database --rename-column=heatindex1
>> --to-name=wetbulbTemp. Flawless.The problem is when I try to insert CSV
>> data into the database using the wee_import.py utility.All fields work on
>> import except the one renamed to "wetbulbTemp"...If I remove the
>> wetbulbTemp field from the import configuration file (*.conf), the import
>> is done without any problem.With the field renamed "wetbulbTemp", I get the
>> following message:*
>>
>> Using WeeWX configuration file /etc/weewx/weewx.conf
>> Starting wee_import...
>> A CSV import from source file '/home/pi/Documents/Bresser7in1/data5.csv'
>> has been requested.
>> The following options will be used:
>>       config=/etc/weewx/weewx.conf,
>> import-config=/home/pi/Documents/Bresser7in1/csv-Bresser.conf
>>       source=/home/pi/Documents/Bresser7in1/data5.csv, from=None, to=None
>>       dry-run=True, calc_missing=True, ignore_invalid_data=True
>>       slice=250, interval=conf, date/time_string_format=%Y-%m-%d %H:%M:%S
>>       delimiter=',', rain=cumulative, wind_direction=[0.0, 360.0]
>>       UV=True, radiation=True
>> Using database binding 'wx_binding', which is bound to database
>> 'weewx.sdb'
>> Destination table 'archive' unit system is '0x01' (US).
>> Missing derived observations will be calculated.
>> This is a dry run, imported data will not be saved to archive.
>> Starting dry run import ...
>> Obtaining raw import data for period 1 ...
>> The following imported field-to-WeeWX field map will be used:
>>       source field 'dateTime' in units 'unix_epoch' --> WeeWX field
>> 'dateTime'
>>       source field 'barometer' in units 'hPa' --> WeeWX field 'barometer'
>>       source field 'inTemp' in units 'degree_C' --> WeeWX field 'inTemp'
>>       source field 'outTemp' in units 'degree_C' --> WeeWX field 'outTemp'
>>       source field 'inHumidity' in units 'percent' --> WeeWX field
>> 'inHumidity'
>>       source field 'outHumidity' in units 'percent' --> WeeWX field
>> 'outHumidity'
>>       source field 'windSpeed' in units 'km_per_hour' --> WeeWX field
>> 'windSpeed'
>>       source field 'windDir' in units 'degree_compass' --> WeeWX field
>> 'windDir'
>>       source field 'windGust' in units 'km_per_hour' --> WeeWX field
>> 'windGust'
>>       source field 'rainRate' in units 'mm_per_hour' --> WeeWX field
>> 'rainRate'
>>       source field 'rain' in units 'mm' --> WeeWX field 'rain'
>>       source field 'dewpoint' in units 'degree_C' --> WeeWX field
>> 'dewpoint'
>>       source field 'windchill' in units 'degree_C' --> WeeWX field
>> 'windchill'
>>       source field 'radiation' in units 'watt_per_meter_squared' -->
>> WeeWX field 'radiation'
>>       source field 'UV' in units 'uv_index' --> WeeWX field 'UV'
>>       source field 'extraTemp1' in units 'degree_C' --> WeeWX field
>> 'extraTemp1'
>>       source field 'extraTemp2' in units 'degree_C' --> WeeWX field
>> 'extraTemp2'
>>       source field 'extraTemp3' in units 'degree_C' --> WeeWX field
>> 'extraTemp3'
>>       source field 'extraTemp4' in units 'degree_C' --> WeeWX field
>> 'extraTemp4'
>>       source field 'extraHumid1' in units 'percent' --> WeeWX field
>> 'extraHumid1'
>>       source field 'extraHumid2' in units 'percent' --> WeeWX field
>> 'extraHumid2'
>>       source field 'extraHumid3' in units 'percent' --> WeeWX field
>> 'extraHumid3'
>>       source field 'extraHumid4' in units 'percent' --> WeeWX field
>> 'extraHumid4'
>>       source field 'wetbulbTemp' in units 'degree_C' --> WeeWX field
>> 'wetbulbTemp'
>> Raw import data read successfully for period 1.
>> Mapping raw import data for period 1 ...
>> Traceback (most recent call last):
>>    File "/usr/share/weewx/wee_import", line 900, in <module>
>>      hand()
>>    File "/usr/share/weewx/wee_import", line 830, in main
>>      source_obj.run()
>>    File "/usr/share/weewx/weeimport/weeimport.py", line 421, in run
>>      _mapped_data = self.mapRawData(_raw_data, self.archive_unit_sys)
>>    File "/usr/share/weewx/weeimport/weeimport.py", line 981, in mapRawData
>>      weewx.units.obs_group_dict[_field])
>>    File "/usr/lib/python3.9/collections/__init__.py", line 941, in
>> __getitem__
>>      return self.__missing__(key) # support subclasses that define
>> __missing__
>>    File "/usr/lib/python3.9/collections/__init__.py", line 933, in
>> __missing__
>>      raiseKeyError(key)
>> *KeyError: 'wetbulbTemp'*
>>
>>
>>
>> *I couldn't find any help in the WeeWX documentation on this.What is
>> happening with this renamed field and what is the solution to integrate the
>> CSV data of this field into my modified weewx.sdb database?*
>>
>> Thank you...
>>
> --
> You received this message because you are subscribed to the Google Groups
> "weewx-user" group.
> To unsubscribe from this group and stop receiving emails from it, send an
> email to [email protected].
> To view this discussion on the web visit
> https://groups.google.com/d/msgid/weewx-user/dbf90df9-0cee-465d-89b1-86b2c77076ebn%40googlegroups.com
> <https://groups.google.com/d/msgid/weewx-user/dbf90df9-0cee-465d-89b1-86b2c77076ebn%40googlegroups.com?utm_medium=email&utm_source=footer>
> .
>

-- 
You received this message because you are subscribed to the Google Groups 
"weewx-user" group.
To unsubscribe from this group and stop receiving emails from it, send an email 
to [email protected].
To view this discussion on the web visit 
https://groups.google.com/d/msgid/weewx-user/CADhm9YeJuV28gYTn8WNR2dr7YFdT5XoSUgPBq9gwB9t_VwqoaQ%40mail.gmail.com.

Reply via email to